Square footage is the wrong starting point
People search "what size generator to run a 1500 sq ft house" because floor area is the number they know. It tells you almost nothing about power. A small house with a well pump, an electric range and central air needs more generator than a big house heated by gas with a fridge and some lights on the list.
What matters is the list. Write down the appliances you can't go without during an outage, then split them into two groups:
- Must run together: refrigerator, freezer, furnace blower, sump pump or well pump, a few lights, phone chargers, the Wi-Fi router.
- Can take turns: microwave, coffee maker, washing machine, window AC, hair dryer.
The second group is where most people overspend. You don't need to run the microwave and the coffee maker at the same moment, so they don't both belong in the total.
How to add it up
Every motor needs a burst of extra power for a second or two when it starts. A refrigerator compressor, a well pump and an air conditioner all do this. Resistive loads such as toasters, space heaters and incandescent bulbs don't.
So the sum has two parts. An electric utility's sizing worksheet sets it out the same way: total the running watts, then add the highest additional starting watts of a single item to get your starting total [13].
- Add the running watts of everything in the "must run together" group.
- Find the one appliance with the biggest starting surge and add that surge on top.
- Compare the running total against the generator's running watts and the starting total against its starting watts.
- Check the running total sits at or below 0.8 of the generator's running rating, so the unit isn't working flat out for hours.
You only add one surge because motors rarely start at the exact same instant. If your fridge and well pump do kick on together and the generator stalls, stagger them by switching one breaker on a little later.
The calculator at the top of this page does this sum with appliance figures read from real manufacturer spec sheets. The table below shows what each appliance draws.
| Air compressor | Workshop and tools | 1,338 | 1,500 to 2,500 | 7,500 (chart) | 11.2 | 6,000 W |
|---|---|---|---|---|---|---|
| Box fan | Around the house | 96 | 50 to 200 | 96 | 0.8 | 2,000 W |
| Ceiling fan | Around the house | 42 | 15 to 75 | 42 | 0.4 | 2,000 W |
| Central AC (2 ton) | Heating and cooling | 2,472 | 2,000 to 2,500 | 4,500 (chart) | 10.3 A at 240 V | 4,000 W |
| Central AC (3 ton) | Heating and cooling | 3,240 | 3,000 to 3,500 | 6,000 (chart) | 13.5 A at 240 V | 5,500 W |
| Central AC (4 ton) | Heating and cooling | 5,376 | 4,000 to 5,000 | 8,000 (chart) | 22.4 A at 240 V | 6,500 W |
| Circular saw (7-1/4 inch) | Workshop and tools | 1,800 | 1,200 to 1,800 | 3,600 (chart) | 15 | 3,000 W |
| Coffee maker | Kitchen | 938 | 600 to 600 | 938 | 7.8 | 2,000 W |
| CPAP machine | Medical | 172 | 60 to 120 | 172 | 1.4 | 2,000 W |
| Dehumidifier | Around the house | 500 | not published | 500 | 4.2 | 2,000 W |
| Desktop computer | Electronics | 200 | 600 to 800 | 200 | 1.7 | 2,000 W |
| Dishwasher | Kitchen | 1,068 | 1,200 to 2,400 | 1,068 | 8.9 | 2,000 W |
| Electric dryer | Laundry | 5,600 | 4,000 to 6,000 | 5,600 | 23.3 A at 240 V | 6,000 W |
| Electric range | Kitchen | 12,100 | 2,100 to 2,100 | 12,100 | 50.4 A at 240 V | 15,000 W |
| Electric water heater | Water and pumps | 4,500 | 3,000 to 4,500 | 4,500 | 18.8 A at 240 V | 4,500 W |
| EV charger (Level 1) | Around the house | 1,440 | not published | 1,440 | 12 | 2,000 W |
| Freezer | Kitchen | 600 | 100 to 500 | 1,000 (chart) | 5 | 2,000 W |
| Furnace blower | Heating and cooling | 750 | 300 to 800 | 1,600 (chart) | 6.3 | 2,000 W |
| Garage door opener | Around the house | 390 | 720 to 720 | 1,420 (chart) | 3.3 | 2,000 W |
| Gas dryer | Laundry | 960 | not published | 960 | 8 | 2,000 W |
| Hair dryer | Around the house | 1,875 | 1,800 to 1,800 | 1,875 | 15.6 | 2,000 W |
| Heat pump | Heating and cooling | 3,456 | 3,000 to 3,500 | 6,000 (chart) | 14.4 A at 240 V | 5,500 W |
| Hot tub | Water and pumps | 8,880 | not published | 8,880 | 37 A at 240 V | 9,000 W |
| LED lights | Around the house | 9 | 8 to 15 | 9 | 0.1 | 2,000 W |
| Microwave | Kitchen | 1,515 | 1,000 to 1,500 | 1,515 | 12.6 | 2,000 W |
| MIG welder (140 A, 120 V) | Workshop and tools | 2,400 | 1,800 to 2,500 | 5,000 (chart) | 20 | 4,000 W |
| Mini fridge | Kitchen | 130 | 50 to 100 | 600 (chart) | 1.1 | 2,000 W |
| Oxygen concentrator | Medical | 330 | not published | 330 | 2.8 | 2,000 W |
| Phone charger | Electronics | 20 | 20 to 100 | 20 | 0.2 | 2,000 W |
| Refrigerator | Kitchen | 780 | 150 to 400 | 1,200 (chart) | 6.5 | 2,000 W |
| RV air conditioner | RV | 1,596 | 1,500 to 2,500 | 4,500 (chart) | 13.3 | 4,000 W |
| Slow cooker | Kitchen | 290 | 170 to 270 | 290 | 2.4 | 2,000 W |
| Space heater | Around the house | 1,500 | 750 to 1,500 | 1,500 | 12.5 | 2,000 W |
| Starlink | Electronics | 100 | not published | 100 | 0.8 | 2,000 W |
| Sump pump (1/2 HP) | Water and pumps | 936 | 800 to 1,050 | 2,150 (chart) | 7.8 | 2,000 W |
| Sump pump (1/3 HP) | Water and pumps | 624 | 500 to 800 | 1,600 (chart) | 5.2 | 2,000 W |
| Table saw (10 inch) | Workshop and tools | 1,800 | 1,800 to 3,000 | 6,000 (chart) | 15 | 5,500 W |
| Toaster oven | Kitchen | 1,500 | not published | 1,500 | 12.5 | 2,000 W |
| TV | Electronics | 219 | 80 to 400 | 219 | 1.8 | 2,000 W |
| Washing machine | Laundry | 720 | 500 to 1,000 | 2,300 (chart) | 6 | 2,000 W |
| Well pump (1 HP) | Water and pumps | 1,409 | 1,000 to 2,000 | 4,000 (chart) | 5.9 A at 240 V | 3,500 W |
| Well pump (1/2 HP) | Water and pumps | 851 | 750 to 1,000 | 2,000 (chart) | 3.5 A at 240 V | 3,500 W |
| Wi-Fi router | Electronics | 7 | 10 to 20 | 7 | 0.1 | 2,000 W |
| Window AC (12,000 Btu) | Heating and cooling | 1,035 | 900 to 1,200 | 2,400 (chart) | 8.6 | 2,000 W |
| Window AC (5,000 Btu) | Heating and cooling | 445 | 450 to 600 | 1,200 (chart) | 3.7 | 2,000 W |
| Window AC (8,000 Btu) | Heating and cooling | 710 | 900 to 1,200 | 2,400 (chart) | 5.9 | 2,000 W |
Typical sizes by what you want to run
Most homes land in one of three bands. The size chart below is computed from the same appliance table, so the figures move when the data does.
| Generator size | Starting assumed W | Starting basis | Runs alone, of 46 | Biggest motor it starts |
|---|---|---|---|---|
| 2,000 W | 2,545 | median ratio 1.27 over 17 models | 31 | Window AC (12,000 Btu) (2,400 W) |
| 2,500 W | 3,077 | median ratio 1.23 over 3 models | 31 | Window AC (12,000 Btu) (2,400 W) |
| 3,000 W | 3,750 | median ratio 1.25 over 10 models | 32 | Circular saw (7-1/4 inch) (3,600 W) |
| 3,500 W | 4,375 | median ratio 1.25 over 18 models | 34 | Well pump (1 HP) (4,000 W) |
| 4,000 W | 5,128 | median ratio 1.28 over 13 models | 37 | MIG welder (140 A, 120 V) (5,000 W) |
| 4,500 W | 5,000 | median ratio 1.11 over 2 models | 38 | MIG welder (140 A, 120 V) (5,000 W) |
| 5,000 W | 5,500 | median ratio 1.1 over 1 model | 38 | MIG welder (140 A, 120 V) (5,000 W) |
| 5,500 W | 6,849 | median ratio 1.25 over 15 models | 41 | Central AC (3 ton) (6,000 W) |
| 6,000 W | 7,500 | median ratio 1.25 over 1 model | 43 | Air compressor (7,500 W) |
| 6,500 W | 8,125 | median ratio 1.25 over 7 models | 44 | Central AC (4 ton) (8,000 W) |
| 7,000 W | 8,750 | median ratio 1.25 over 3 models | 44 | Central AC (4 ton) (8,000 W) |
| 7,500 W | 9,388 | median ratio 1.25 over 12 models | 44 | Central AC (4 ton) (8,000 W) |
| 8,000 W | 10,000 | median ratio 1.25 over 6 models | 44 | Central AC (4 ton) (8,000 W) |
| 9,000 W | 11,500 | median ratio 1.28 over 5 models | 45 | Central AC (4 ton) (8,000 W) |
| 10,000 W | 13,158 | median ratio 1.32 over 13 models | 45 | Central AC (4 ton) (8,000 W) |
| 12,000 W | 15,130 | median ratio 1.26 over 3 models | 45 | Central AC (4 ton) (8,000 W) |
| 15,000 W | 18,621 | median ratio 1.24 over 6 models | 46 | Central AC (4 ton) (8,000 W) |
Running watts are the size itself. Starting watts are the size times the median starting-to-running ratio of the current generators in that size that publish both figures. An appliance counts when its running watts and its starting watts for sizing both fit. A 240 V appliance also needs a 240 V outlet, so it counts only when a current generator of that size in our data has one.
Essentials only. Fridge, freezer, a few lights, chargers, the router and a TV. A small inverter generator can often carry this. See what a 3500 watt generator will run for the full yes or no list.
Essentials plus heat or water. Add a gas furnace blower, a sump pump or a 1/2 HP well pump. Starting surges push you toward the middle of the portable range. What a 5000 watt generator will run and what a 7500 watt generator will run cover this band.
Most of the house. Central air, an electric water heater, an electric range or a well pump on 240 V. These need 240 V output and a lot of running watts, which puts you at the top of the portable range or into home standby.
The 240 V question
Many big loads in a US house run on 240 V: central air, electric dryers, electric ranges, electric water heaters and some well pumps. A generator can only power those if it has a 240 V outlet, usually a NEMA L14-30 [19] or 14-50 [18]. Many small inverter generators are 120 V only.
Check the appliance's rating plate or spec sheet before you size. The well pump (1 HP) and electric water heater pages show the voltage each sampled model lists.
Portable or standby?
A portable generator covers essentials for the least money, but you have to wheel it out, fuel it and run it at least 20 ft from the house with the exhaust pointed away, per the U.S. Consumer Product Safety Commission [7]. A standby unit sits outside on a pad, runs on natural gas or propane and starts on its own.
Standby makes sense when you want the whole house, including central air, without anyone touching anything. The portable vs standby guide covers cost and fuel trade-offs. For a sense of scale, the Generac Guardian 22 kW is rated at 19,500 W on natural gas, while a popular small inverter like the Honda EU2200i is rated at 1,800 W running.
Connecting a generator to the house
Extension cords from the generator to each appliance work for a fridge and a few lamps. To power hardwired loads like a furnace or a well pump, the generator has to feed your panel through a transfer switch or an interlock kit. Either one must be installed by a licensed electrician.
OSHA's guidance is plain: never attach a generator directly to a structure's electrical system unless a qualified electrician has installed it with a transfer switch, because backfeed can energize utility lines and endanger line workers [10]. The interlock kit vs transfer switch guide explains the difference.
Safety before you size
Run a portable generator outside only, at least 20 ft from the house, with the exhaust directed away from the home and other buildings. Never run it inside a home, garage, basement, crawlspace or shed, even with doors and windows open [7]. Put battery-operated or battery-backup CO alarms on each floor. The generator safety guide has the full CPSC list.
FAQ
What size generator do I need for a 1,500 sq ft house?
Floor area doesn't set the size. Your appliance list does. A 1,500 sq ft house on gas heat with a fridge, freezer, furnace blower and lights needs far less than the same house with central air and a well pump. Add running watts, add the biggest starting surge, and use the calculator to get a size.
Can a portable generator run a whole house?
It can run most of a house without big 240 V loads, or if you take turns with them. Central air, electric ranges and electric water heaters each use a large share of a portable unit's output. For everything at once with no juggling, people usually move to a standby unit sized by an electrician's load calculation.
Why add only one starting surge?
Motor surges last a second or two, and two motors rarely start at the same instant. Adding the largest single surge to the running total covers the worst normal case, which is how utility sizing worksheets do it. If two motors do clash, turn one breaker on a few seconds after the other.
Why leave headroom below the rated running watts?
Generators run cooler and steadier below their full rating, and appliance draw varies with age and temperature. This site applies a continuous-load factor of 0.8 to the running rating, a common sizing convention, so the recommended size covers your running total with room to spare during a long outage.
Do I need a transfer switch to run my house on a generator?
To power hardwired loads through your panel, yes: a transfer switch or an interlock kit, installed by a licensed electrician. Without one, a generator can backfeed utility lines and endanger line workers, as OSHA warns. Extension cords plugged straight into the generator are the only way to skip it.