Predator 1800 Portable Generator
Predator, Open frame
- Running
- 1,400 W
- Starting
- 1,800 W
- Weight
- 60 lb
A sump pump (1/3 HP) is rated 624 W on the nameplate, the median of 5 sampled models. Champion's generator chart lists 500 to 800 W running. Sizing uses 1,600 W to start: the top of Champion's starting band, as no maker prints one. The smallest size that covers it alone is 2,000 W.
| Figure | Value | Where it comes from |
|---|---|---|
| Rated draw (nameplate) | 624 W | Median of 5 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating. |
| Typical running (generator maker's chart) | 500 to 800 W | Champion generator wattage chart |
| Starting (generator maker's chart) | 1,000 to 1,600 W | Champion generator wattage chart |
| Starting watts for sizing | 1,600 W | Used because no sampled maker prints a surge, so it is the top of Champion's starting band. |
| Amps at 120 V | 5.2 A | Rated draw divided by 120 V. |
What was sampled: 1/3 HP class submersible sump pump, 115 to 120 V.
Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.
| Printed as, document, checked | |||||
|---|---|---|---|---|---|
| Superior Pump | 92341 | 4.1 | not published | 492 | Amps, superiorpump.com, checked |
| Superior Pump | 92351 | 7.6 | not published | 912 | Amps, superiorpump.com, checked |
| Liberty Pumps | 257 | 5.2 | not published | 624 | AMPS, libertypumps.com, checked |
| Liberty Pumps | 237 | 5.2 | not published | 624 | AMPS, libertypumps.com, checked |
| Zoeller | M53 | 9.7 | not published | 1,164 | Amps, zoellerpumps.com, checked |
The smallest listed size that covers 624 W running and 1,600 W starting on its own is 2,000 W.
The smallest current generators in our data that run it alone:
Predator, Open frame
Honda Power Equipment, Inverter
Honda Power Equipment, Inverter
Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.
| Question | Generator running W | Generator starting W | Answer |
|---|---|---|---|
| Will a 2,000 watt generator run a sump pump (1/3 HP)? | 2,000 | 2,545 | Yes |
| Will a 3,500 watt generator run a sump pump (1/3 HP)? | 3,500 | 4,375 | Yes |
| Will a 5,000 watt generator run a sump pump (1/3 HP)? | 5,000 | 5,500 | Yes |
| Will a 7,500 watt generator run a sump pump (1/3 HP)? | 7,500 | 9,388 | Yes |
Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.
| Running at once | Running total W | Peak at the largest start W | Runs |
|---|---|---|---|
| Sump pump (1/3 HP) | 624 | 1,600 | Yes |
| Sump pump (1/3 HP) + LED lights | 633 | 1,609 | Yes |
| Sump pump (1/3 HP) + LED lights + phone charger | 653 | 1,629 | Yes |
| Sump pump (1/3 HP) + LED lights + phone charger + TV | 872 | 1,848 | Yes |
| Sump pump (1/3 HP) + LED lights + phone charger + TV + refrigerator | 1,652 | 2,628 | Yes |
4,500 W running 4,500 W starting
8,880 W running 8,880 W starting
936 W running 2,150 W starting
1,409 W running 4,000 W starting
851 W running 2,000 W starting
| Spec | Value | Printed as | Document | Checked |
|---|---|---|---|---|
| Superior Pump 92341: rated amps | 4.1 A | Amps | superiorpump.com (product page html) | |
| Superior Pump 92351: rated amps | 7.6 A | Amps | superiorpump.com (product page html) | |
| Liberty Pumps 257: rated amps | 5.2 A | AMPS | libertypumps.com (spec sheet pdf) | |
| Liberty Pumps 237: rated amps | 5.2 A | AMPS | libertypumps.com (spec sheet pdf) | |
| Zoeller M53: rated amps | 9.7 A | Amps | zoellerpumps.com (spec sheet pdf) |
The 5 models we sampled print a median of 624 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 500 to 800 W as typical running watts. Plan for 1,600 W when it starts.
At 120 V, 624 W works out to 5.2 A. That is the median nameplate draw divided by 120 V. A sump pump (1/3 HP) draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.
The smallest listed size that covers a sump pump (1/3 HP) on its own is 2,000 W. That covers 624 W running and 1,600 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Predator 1800 Portable Generator at 1,400 W running.
We size a sump pump (1/3 HP) at 1,600 W to start, because no sampled maker prints a surge, so it is the top of Champion's starting band. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.