Appliance wattage chart

This chart lists 46 household appliances and the watts each one draws. Every rated figure is the median of 3 to 5 real models, 201 in all, read from the makers' own spec sheets and manuals. Where no maker prints a starting surge, 22 motor loads are sized from the top of a generator maker's chart band.

Every appliance

Watts for 46 appliances Checked on
Coffee maker Kitchen 938 600 to 600 938 7.8 2,000 W
Dishwasher Kitchen 1,068 1,200 to 2,400 1,068 8.9 2,000 W
Electric range Kitchen 12,100 2,100 to 2,100 12,100 50.4 A at 240 V 15,000 W
Freezer Kitchen 600 100 to 500 1,000 (chart) 5 2,000 W
Microwave Kitchen 1,515 1,000 to 1,500 1,515 12.6 2,000 W
Mini fridge Kitchen 130 50 to 100 600 (chart) 1.1 2,000 W
Refrigerator Kitchen 780 150 to 400 1,200 (chart) 6.5 2,000 W
Slow cooker Kitchen 290 170 to 270 290 2.4 2,000 W
Toaster oven Kitchen 1,500 not published 1,500 12.5 2,000 W
Central AC (2 ton) Heating and cooling 2,472 2,000 to 2,500 4,500 (chart) 10.3 A at 240 V 4,000 W
Central AC (3 ton) Heating and cooling 3,240 3,000 to 3,500 6,000 (chart) 13.5 A at 240 V 5,500 W
Central AC (4 ton) Heating and cooling 5,376 4,000 to 5,000 8,000 (chart) 22.4 A at 240 V 6,500 W
Furnace blower Heating and cooling 750 300 to 800 1,600 (chart) 6.3 2,000 W
Heat pump Heating and cooling 3,456 3,000 to 3,500 6,000 (chart) 14.4 A at 240 V 5,500 W
Window AC (12,000 Btu) Heating and cooling 1,035 900 to 1,200 2,400 (chart) 8.6 2,000 W
Window AC (5,000 Btu) Heating and cooling 445 450 to 600 1,200 (chart) 3.7 2,000 W
Window AC (8,000 Btu) Heating and cooling 710 900 to 1,200 2,400 (chart) 5.9 2,000 W
Electric dryer Laundry 5,600 4,000 to 6,000 5,600 23.3 A at 240 V 6,000 W
Gas dryer Laundry 960 not published 960 8 2,000 W
Washing machine Laundry 720 500 to 1,000 2,300 (chart) 6 2,000 W
Box fan Around the house 96 50 to 200 96 0.8 2,000 W
Ceiling fan Around the house 42 15 to 75 42 0.4 2,000 W
Dehumidifier Around the house 500 not published 500 4.2 2,000 W
EV charger (Level 1) Around the house 1,440 not published 1,440 12 2,000 W
Garage door opener Around the house 390 720 to 720 1,420 (chart) 3.3 2,000 W
Hair dryer Around the house 1,875 1,800 to 1,800 1,875 15.6 2,000 W
LED lights Around the house 9 8 to 15 9 0.1 2,000 W
Space heater Around the house 1,500 750 to 1,500 1,500 12.5 2,000 W
Electric water heater Water and pumps 4,500 3,000 to 4,500 4,500 18.8 A at 240 V 4,500 W
Hot tub Water and pumps 8,880 not published 8,880 37 A at 240 V 9,000 W
Sump pump (1/2 HP) Water and pumps 936 800 to 1,050 2,150 (chart) 7.8 2,000 W
Sump pump (1/3 HP) Water and pumps 624 500 to 800 1,600 (chart) 5.2 2,000 W
Well pump (1 HP) Water and pumps 1,409 1,000 to 2,000 4,000 (chart) 5.9 A at 240 V 3,500 W
Well pump (1/2 HP) Water and pumps 851 750 to 1,000 2,000 (chart) 3.5 A at 240 V 3,500 W
CPAP machine Medical 172 60 to 120 172 1.4 2,000 W
Oxygen concentrator Medical 330 not published 330 2.8 2,000 W
RV air conditioner RV 1,596 1,500 to 2,500 4,500 (chart) 13.3 4,000 W
Air compressor Workshop and tools 1,338 1,500 to 2,500 7,500 (chart) 11.2 6,000 W
Circular saw (7-1/4 inch) Workshop and tools 1,800 1,200 to 1,800 3,600 (chart) 15 3,000 W
MIG welder (140 A, 120 V) Workshop and tools 2,400 1,800 to 2,500 5,000 (chart) 20 4,000 W
Table saw (10 inch) Workshop and tools 1,800 1,800 to 3,000 6,000 (chart) 15 5,500 W
Desktop computer Electronics 200 600 to 800 200 1.7 2,000 W
Phone charger Electronics 20 20 to 100 20 0.2 2,000 W
Starlink Electronics 100 not published 100 0.8 2,000 W
TV Electronics 219 80 to 400 219 1.8 2,000 W
Wi-Fi router Electronics 7 10 to 20 7 0.1 2,000 W

Rated draw is the median nameplate figure of the sampled models, which is a maximum rating. Typical running is the generator maker's chart band. A starting figure marked "(chart)" is the top of that chart's starting band, used because no sampled maker prints a surge. Click a column heading to sort.

Add up your own list

Running several appliances at once? The sizing calculator adds their running watts, puts the largest starting surge on top and suggests a generator size.

What each generator size runs

Each page checks every appliance on this chart against one generator size, alone and in common combinations.

Page data checked on