How the data is collected and checked
The site holds 243 models from 13 brands and 46 appliances. Every figure is read from the maker's own spec sheet, owner's manual or product page and stored with its link and checked date. 215 models match a second document. Every rule and constant used for sizing is listed below.
Where the figures come from
Each model is one manufacturer model number. Its figures are read from the maker's documents, in this order of preference: the owner's manual for electrical ratings, the spec sheet for weight and dimensions, the newest document over an older one, and the manufacturer over a retailer. Retailer pages are used only as a cross-check. Amazon is never a source.
A value the maker does not publish is stored as not published and shown that way. It is never estimated, averaged or filled from another model. A published zero stays a zero.
1,063 source documents are on file. 1,039 of them are archived with a SHA-256 fingerprint, so a later change to the maker's file can be detected. Documents that could not be archived carry a note saying why. Harbor Freight manuals are read and cited by URL, not hosted, per Harbor Freight's terms.
| Document type | Count |
|---|---|
| Owner's manual (PDF) | 2,207 |
| Maker's product page | 1,707 |
| Spec sheet (PDF) | 718 |
| Maker's store data feed | 228 |
| Other maker document | 96 |
| Energy Star database | 13 |
Cross-checks and status
Running watts, starting watts, battery Wh, weight and tank size are checked against a second document from the maker. A gap over 5% or a different outlet set marks the model as a mismatch, and the record keeps both values and both links in a note. A model with only one document is marked not checked.
| Result | Count |
|---|---|
| Matches a second document | 215 |
| Differs by more than 5% from a second document (both values kept in a note) | 17 |
| Only one document found | 11 |
| Status | Count |
|---|---|
| Current: sold by the maker today | 217 |
| Unavailable: listed by the maker but out of stock or regional only when checked | 14 |
| Discontinued: the maker says so, or the page is gone and a successor exists | 12 |
Discontinued models keep their pages with a link to the successor. They are left out of rankings, tables of current models and the calculator.
Appliance wattage
No primary document exists for "a refrigerator", so each appliance stores 3 to 5 named, real models, 201 in all across 46 appliances. Each sample's rated amps or watts is read from that model's spec sheet or tech sheet and stored with the field name as printed. Watts are the printed watts, or the printed amps times the appliance's voltage.
The rated draw shown for an appliance is the median over its samples. Nameplate amps are maximum ratings, so the rated draw is a ceiling more than an average. Sizing uses it anyway, so a recommendation errs on the generous side.
Beside it, each appliance shows the typical running band from a generator maker's wattage chart: the Champion chart for 39 appliances and the Honda chart for 7. Where the chart has no row for the exact appliance, the nearest row is used and the page says so: Heat pump, Window AC (12,000 Btu) and Window AC (8,000 Btu). No maker's chart lists Dehumidifier, EV charger (Level 1), Gas dryer, Hot tub, Oxygen concentrator, Starlink or Toaster oven.
Starting watts and locked rotor amps
Starting watts for sizing come from a surge figure the maker prints. When none of the samples prints one, a motor load uses the top of the generator maker's chart band, so a motor is never assumed to start for free. Anything else starts at its running watts. Today 0 appliances have a printed surge figure, and 22 of the 30 motor loads size from the chart band.
Locked rotor amps (LRA), printed on many air conditioner and refrigeration sheets, is the current a stalled motor draws for a fraction of a second. LRA times voltage is shown on appliance pages as inrush, a fact about the motor. It is not used for sizing, because it runs several times higher than the surge a generator maker's chart lists for the same load.
Sizing a load
A list of appliances is totaled in two parts: the running watts of everything on it, and that total plus the largest single starting surge on top. Only one surge is added, because motors rarely start at the same instant.
The recommended size is the larger of the running total divided by the continuous-load factor of 0.8 [5] and the starting peak, rounded up to the next listed size. The factor is a sizing convention, not a verified rule; see the constants table.
A model runs a list when the running total fits its running watts and the starting peak fits its starting watts. A model that publishes no starting figure is treated as starting at its running watts. A 240 V appliance also needs a model with a 240 V outlet.
Generator sizes
A generator belongs to the listed size closest to its highest published running watts. A model exactly halfway between two sizes goes to the larger one. The smallest and largest sizes extend half a step beyond their own size; models outside that range get no size page.
A size's shopping page is built only when at least 6 current generators fall in it.
| Size | From W | Up to, not including W | Current generators | Shopping page |
|---|---|---|---|---|
| 2,000 W | 1,750 | 2,250 | 17 | /generators/2000-watt/ |
| 2,500 W | 2,250 | 2,750 | 3 | under the gate of 6 |
| 3,000 W | 2,750 | 3,250 | 10 | /generators/3000-watt/ |
| 3,500 W | 3,250 | 3,750 | 18 | /generators/3500-watt/ |
| 4,000 W | 3,750 | 4,250 | 13 | /generators/4000-watt/ |
| 4,500 W | 4,250 | 4,750 | 2 | under the gate of 6 |
| 5,000 W | 4,750 | 5,250 | 1 | under the gate of 6 |
| 5,500 W | 5,250 | 5,750 | 15 | /generators/5500-watt/ |
| 6,000 W | 5,750 | 6,250 | 1 | under the gate of 6 |
| 6,500 W | 6,250 | 6,750 | 7 | /generators/6500-watt/ |
| 7,000 W | 6,750 | 7,250 | 3 | under the gate of 6 |
| 7,500 W | 7,250 | 7,750 | 12 | /generators/7500-watt/ |
| 8,000 W | 7,750 | 8,500 | 6 | /generators/8000-watt/ |
| 9,000 W | 8,500 | 9,500 | 5 | under the gate of 6 |
| 10,000 W | 9,500 | 11,000 | 15 | /generators/10000-watt/ |
| 12,000 W | 11,000 | 13,500 | 5 | under the gate of 6 |
| 15,000 W | 13,500 | 17,500 | 9 | /generators/15000-watt/ |
| 20,000 W | 17,500 | 21,000 | 8 | /generators/20000-watt/ |
| 22,000 W | 21,000 | 23,000 | 4 | under the gate of 6 |
| 24,000 W | 23,000 | 25,000 | 1 | under the gate of 6 |
| 26,000 W | 25,000 | 27,000 | 4 | under the gate of 6 |
Category pages
Each category page lists the current models that pass one rule. A page is built only when at least 6 current models pass. Below that, the category is not a page.
| Page | Table | Rule | Current models |
|---|---|---|---|
| Dual fuel generators | Generators | Portable and inverter generators that list two or more fuels. | 59 |
| Propane generators | Generators | Generators that list propane as a fuel. | 79 |
| Natural gas generators for home | Generators | Generators that list natural gas as a fuel. | 36 |
| Diesel generators (no page: under the gate) | Generators | Generators that list diesel as a fuel. | 1 |
| Inverter generators | Generators | Generators the maker sells as inverter generators. | 66 |
| Home standby generators | Generators | Permanently installed home standby generators. | 20 |
| Portable generators | Generators | Open-frame and inverter generators, everything that is not standby. | 143 |
| Generators for RVs | Generators | Generators with an RV receptacle: a TT-30R (30 amp RV) or a 14-50R (50 amp). | 72 |
| Portable generators for camping | Generators | Inverter generators with 3,000 running watts or less. | 31 |
| Backup generators for home | Generators | Standby generators, and portable generators with at least 5,000 running watts. | 96 |
| Quiet generators | Generators | Generators with a published reading of 60 dBA or less at 25% load or lighter. | 13 |
| Generators for welders | Generators | Portable generators with 240 V output and at least 5,000 running watts. | 76 |
| Generators for food trucks | Generators | Portable generators with at least 5,000 running watts and a 30 or 50 amp receptacle. | 76 |
| Job site generators | Generators | Portable generators with at least 3,000 running watts. | 118 |
| Generators with a 50 amp outlet | Generators | Generators with a 50 amp receptacle: a 14-50R or a CS6365. | 36 |
| Generators with a 30 amp outlet | Generators | Generators with a 30 amp receptacle: a TT-30R, an L5-30R or an L14-30R. | 127 |
| Remote start generators | Generators | Generators the maker lists with remote start. | 54 |
| CARB compliant generators | Generators | Generators the maker lists as CARB compliant. | 24 |
| Parallel capable generators | Generators | Generators the maker lists as parallel capable. | 56 |
| Power stations for CPAP | Power stations | Power stations with at least 500 Wh of battery. | 55 |
| Portable power stations for camping | Power stations | Power stations that weigh 35 lb or less. | 32 |
| Power stations for home backup | Power stations | Home battery systems, and power stations with at least 2,000 Wh of battery. | 30 |
Runtime and fuel use
Runtime and fuel use come from the figures the maker publishes at stated loads. Fuel use per hour is treated as a straight line between the loads the maker publishes. Between two published loads the line is interpolated. Outside them the line is extended only between 25% and 100% load, and only when two loads are published. Anything else is left blank rather than guessed. Every figure that is not published is labeled interpolated or extrapolated where it appears.
Fuel cost is not stored. The runtime calculator works it out from the price per gallon or per thousand cubic feet that you type in.
Power station runtimes use the battery's Wh times an inverter efficiency of 0.85 [4], a maker-published rule of thumb, divided by the load.
Rankings and alternatives
Where models are ranked, the most complete record comes first. A model scores one point for each of these the maker publishes:
- Starting watts
- Weight
- Dimensions
- Noise with distance and load
- Runtime at a stated load, or battery capacity
- Fuel tank or battery Wh
- Outlets
- Warranty
- List price
- Cross-checked against a second document
Ties go to the lower list price per running watt, with unpriced models last, then to the name.
The closest alternatives to a model are the current models of the same kind with the smallest weighted gap across the factors below. Each gap is relative to the larger of the two figures and capped at a full gap. A noise gap of 10 dB counts as a full gap, and noise is compared only at the same distance and load. A figure missing on either side counts as half a full gap.
| Factor | Weight |
|---|---|
| Running watts | 3 |
| Fuel types shared | 2 |
| Battery Wh (power stations only) | 2 |
| Weight | 1 |
| Noise at the same distance and load | 1 |
| List price | 1 |
Rankings and alternatives never read buy links. A test in the site's code removes every buy link and checks that no ranking changes. See the affiliate disclosure.
Constants
These are the only fixed numbers the calculations use. Each links to its source below. A constant marked unverified has no primary source read yet; it is presented as a convention, not a fact.
| Constant | Value | Unit | Status | Source | Note |
|---|---|---|---|---|---|
GASOLINE_BTU_PER_GAL | 120,214 | Btu/gal | verified against the source | [1] | Energy content of motor gasoline. EIA updates it annually in Appendix A of the Monthly Energy Review. |
PROPANE_BTU_PER_GAL | 91,452 | Btu/gal | verified against the source | [1] | Energy content of liquid propane. |
DIESEL_BTU_PER_GAL | 137,381 | Btu/gal | verified against the source | [1] | Energy content of diesel fuel. |
NG_BTU_PER_FT3 | 1,000 | Btu/ft3 | verified against the source | [2] | Generac spec sheet convention for natural gas. EIA lists 1,036 Btu per cubic foot; the site follows the basis standby fuel tables are published on. |
LP_BTU_PER_FT3 | 2,500 | Btu/ft3 | verified against the source | [2] | Generac spec sheet convention for propane vapor. |
INVERTER_EFFICIENCY | 0.85 | ratio | verified against the source | [4] | Share of a power station battery that reaches AC outlets after conversion losses. A maker-published rule of thumb, not a measurement of any one unit. |
CONTINUOUS_LOAD_FACTOR | 0.8 | ratio | unverified, presented as a convention | [5] | Sizing convention: keep a long-running load at or under 80% of the running watts. Attributed to the NEC continuous-load rule; the primary text was not read. |
GENERATOR_DISTANCE_FT | 20 | ft | verified against the source | [3] | CPSC: keep portable generators at least 20 feet from doors, windows and vents. Never run one indoors, including garages, basements, crawlspaces and sheds. |
LRA_MULTIPLIER_MIN | 5 | x rated amps | unverified, presented as a convention | [6] | Low end of locked rotor amps as a multiple of full-load amps for small motors. Used only to explain starting surge; nameplate LRA is preferred. |
LRA_MULTIPLIER_MAX | 8 | x rated amps | unverified, presented as a convention | [6] | High end of the same range. |
Sources cited
- U.S. Energy Information Administration, Energy conversion calculators , checked Oct 7, 2026
- Generac Guardian 20-24 kW standby generator spec sheet, fuel consumption note , checked Oct 7, 2026
- U.S. Consumer Product Safety Commission, Portable Generator Hazards safety alert , checked Oct 7, 2026
- Anker SOLIX, How long will a power station last , checked Oct 7, 2026
- SlashGear, What is the 80 percent rule for generators (secondary source) , checked Oct 7, 2026
- Industrial Monitor Direct, Locked rotor amps and NEMA design specifications (secondary source) , checked Oct 7, 2026
- CPSC, What to Know About Generators and Carbon Monoxide , checked Oct 7, 2026
- CPSC news release, winter weather safety tips, March 16, 2026 , checked Oct 7, 2026
- CPSC news release, survival tips after Hurricane Rita , checked Oct 7, 2026
- OSHA Fact Sheet, Using Portable Generators Safely , checked Oct 7, 2026
- North Carolina Office of State Fire Marshal, Optional Standby Systems interpretation (2023 Electrical Code) , checked Oct 7, 2026
- Volusia County, FL, Residential Generator Installations , checked Oct 7, 2026
- Eugene Water & Electric Board, Generator Sizing Considerations , checked Oct 7, 2026
- Champion Power Equipment, What is an Inverter Generator? , checked Oct 7, 2026
- U.S. Energy Information Administration, How electricity is generated , checked Oct 7, 2026
- Ferrellgas, Propane's shelf life makes it the envy of gasoline and diesel , checked Oct 7, 2026
- Leviton 7313-S00, 30 Amp TT-30R receptacle , checked Oct 7, 2026
- Leviton 55050, 50 Amp 14-50R receptacle , checked Oct 7, 2026
- Leviton 2710, 30 Amp L14-30R locking receptacle , checked Oct 7, 2026