How many watts does a ceiling fan use?

A ceiling fan is rated 42 W on the nameplate, the median of 4 sampled models. Champion's generator chart lists 15 to 75 W running. Sizing uses 42 W to start: its running draw, since no maker or chart prints a surge. The smallest size that covers it alone is 2,000 W.

Ceiling fan figures

Ceiling fan: draw, starting watts and amps Checked on
Figure Value Where it comes from
Rated draw (nameplate) 42 W Median of 4 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating.
Typical running (generator maker's chart) 15 to 75 W Champion generator wattage chart
Starting watts for sizing 42 W Used because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown.
Amps at 120 V 0.4 A Rated draw divided by 120 V.

What was sampled: 52 inch residential ceiling fan on high speed, lights off, AC and DC motors.

The models we sampled

Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.

Ceiling fan models sampled Checked on
Printed as, document, checked
Westinghouse Lighting 7305400 Comet 0.53 63 63 Watts (High), westinghouselighting.com, checked
Westinghouse Lighting 7209100 Castle 0.51 61 61 Watts (High), westinghouselighting.com, checked
Hunter 52783 not published 21 21 fan_power_consumption_high_speed_w, data.energystar.gov, checked
Hunter 52729 not published 22 22 fan_power_consumption_high_speed_w, data.energystar.gov, checked

The generator you need

The smallest listed size that covers 42 W running and 42 W starting on its own is 2,000 W.

The smallest current generators in our data that run it alone:

Add it to the calculator with other appliances

Will a 2,000 to 7,500 watt generator run it?

Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.

Ceiling fan on four generator sizes
Question Generator running W Generator starting W Answer
Will a 2,000 watt generator run a ceiling fan? 2,000 2,545 Yes
Will a 3,500 watt generator run a ceiling fan? 3,500 4,375 Yes
Will a 5,000 watt generator run a ceiling fan? 5,000 5,500 Yes
Will a 7,500 watt generator run a ceiling fan? 7,500 9,388 Yes

With other appliances on a 3,500 W generator

Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.

Ceiling fan with other appliances on a 3,500 W generator
Running at once Running total W Peak at the largest start W Runs
Ceiling fan 42 42 Yes
Ceiling fan + LED lights 51 51 Yes
Ceiling fan + LED lights + phone charger 71 71 Yes
Ceiling fan + LED lights + phone charger + TV 290 290 Yes
Ceiling fan + LED lights + phone charger + TV + refrigerator 1,070 1,490 Yes

Every appliance on one chart

Sources

Where each Ceiling fan value comes from
Spec Value Printed as Document Checked
Westinghouse Lighting 7305400 Comet: rated amps 0.53 A Amp (High) westinghouselighting.com (spec sheet pdf)
Westinghouse Lighting 7305400 Comet: rated watts 63 W Watts (High) westinghouselighting.com (spec sheet pdf)
Westinghouse Lighting 7209100 Castle: rated amps 0.51 A Amp (High) westinghouselighting.com (spec sheet pdf)
Westinghouse Lighting 7209100 Castle: rated watts 61 W Watts (High) westinghouselighting.com (spec sheet pdf)
Hunter 52783: rated watts 20.6 W fan_power_consumption_high_speed_w data.energystar.gov (energy star api)
Hunter 52729: rated watts 22.2 W fan_power_consumption_high_speed_w data.energystar.gov (energy star api)

Questions people ask

How many watts does a ceiling fan use?

The 4 models we sampled print a median of 42 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 15 to 75 W as typical running watts. Plan for 42 W when it starts.

How many amps does a ceiling fan draw?

At 120 V, 42 W works out to 0.4 A. That is the median nameplate draw divided by 120 V. A ceiling fan draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.

What size generator does a ceiling fan need?

The smallest listed size that covers a ceiling fan on its own is 2,000 W. That covers 42 W running and 42 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Honda EU1000i at 900 W running.

How many watts does a ceiling fan need to start?

We size a ceiling fan at 42 W to start, because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.

Page data checked on