Predator 5000 Dual-Fuel Super Quiet Inverter Generator
Predator, Dual fuel inverter
- Running
- 3,900 W
- Starting
- 5,000 W
- Weight
- 110 lb
A 4,000 watt generator runs 37 of the 46 appliances in our data on their own. The biggest motor it can start is a MIG welder (140 A, 120 V), sized at 5,000 W to start. We count it as 4,000 W running and 5,128 W starting, the median surge of 13 current 4,000 W generators.
This page treats a 4,000 watt generator as 4,000 W running and 5,128 W starting. The starting figure is 4,000 W times 1.28, the median starting-to-running ratio of 13 current generators in that size band.
An appliance runs alone when its running watts fit within 4,000 W and its starting watts fit within 5,128 W. 3 of the 13 current generators in this size band have a 240 V outlet. Check for one before you plan on a 240 V appliance.
| Air compressor | 1,338 | 7,500 (chart) | No, cannot start it |
|---|---|---|---|
| Box fan | 96 | 96 | Yes |
| Ceiling fan | 42 | 42 | Yes |
| Central AC (2 ton) | 2,472 | 4,500 (chart) | Yes, with a 240 V outlet |
| Central AC (3 ton) | 3,240 | 6,000 (chart) | No, cannot start it |
| Central AC (4 ton) | 5,376 | 8,000 (chart) | No, too many running watts |
| Circular saw (7-1/4 inch) | 1,800 | 3,600 (chart) | Yes |
| Coffee maker | 938 | 938 | Yes |
| CPAP machine | 172 | 172 | Yes |
| Dehumidifier | 500 | 500 | Yes |
| Desktop computer | 200 | 200 | Yes |
| Dishwasher | 1,068 | 1,068 | Yes |
| Electric dryer | 5,600 | 5,600 | No, too many running watts |
| Electric range | 12,100 | 12,100 | No, too many running watts |
| Electric water heater | 4,500 | 4,500 | No, too many running watts |
| EV charger (Level 1) | 1,440 | 1,440 | Yes |
| Freezer | 600 | 1,000 (chart) | Yes |
| Furnace blower | 750 | 1,600 (chart) | Yes |
| Garage door opener | 390 | 1,420 (chart) | Yes |
| Gas dryer | 960 | 960 | Yes |
| Hair dryer | 1,875 | 1,875 | Yes |
| Heat pump | 3,456 | 6,000 (chart) | No, cannot start it |
| Hot tub | 8,880 | 8,880 | No, too many running watts |
| LED lights | 9 | 9 | Yes |
| Microwave | 1,515 | 1,515 | Yes |
| MIG welder (140 A, 120 V) | 2,400 | 5,000 (chart) | Yes |
| Mini fridge | 130 | 600 (chart) | Yes |
| Oxygen concentrator | 330 | 330 | Yes |
| Phone charger | 20 | 20 | Yes |
| Refrigerator | 780 | 1,200 (chart) | Yes |
| RV air conditioner | 1,596 | 4,500 (chart) | Yes |
| Slow cooker | 290 | 290 | Yes |
| Space heater | 1,500 | 1,500 | Yes |
| Starlink | 100 | 100 | Yes |
| Sump pump (1/2 HP) | 936 | 2,150 (chart) | Yes |
| Sump pump (1/3 HP) | 624 | 1,600 (chart) | Yes |
| Table saw (10 inch) | 1,800 | 6,000 (chart) | No, cannot start it |
| Toaster oven | 1,500 | 1,500 | Yes |
| TV | 219 | 219 | Yes |
| Washing machine | 720 | 2,300 (chart) | Yes |
| Well pump (1 HP) | 1,409 | 4,000 (chart) | Yes, with a 240 V outlet |
| Well pump (1/2 HP) | 851 | 2,000 (chart) | Yes, with a 240 V outlet |
| Wi-Fi router | 7 | 7 | Yes |
| Window AC (12,000 Btu) | 1,035 | 2,400 (chart) | Yes |
| Window AC (5,000 Btu) | 445 | 1,200 (chart) | Yes |
| Window AC (8,000 Btu) | 710 | 2,400 (chart) | Yes |
Rated draw is the median nameplate figure of the sampled models. "(chart)" marks a starting figure from the top of a generator maker's chart band, used because no sampled maker prints a surge.
Everything in a list runs at once, with the largest single starting surge on top.
Storm outage Yes
refrigerator, furnace blower, sump pump (1/2 HP), LED lights, TV, Wi-Fi router, 2 x phone charger
2,741 W running, 3,955 W at the largest start.
RV weekend No, cannot start it
RV air conditioner, microwave, LED lights, TV, 2 x phone charger
3,379 W running, 6,283 W at the largest start.
Job site No, cannot start it
circular saw (7-1/4 inch), air compressor, LED lights, phone charger
3,167 W running, 9,329 W at the largest start.
Camping Yes
mini fridge, coffee maker, LED lights, 2 x phone charger
1,117 W running, 1,587 W at the largest start.
CPAP night Yes
CPAP machine, LED lights, phone charger
201 W running, 201 W at the largest start.
The totals update as you tick. They add the running watts and put the largest starting surge on top, against 4,000 W running and 5,128 W starting.
Running total 1,028 W of 4,000 W
Peak at the largest start 1,448 W of 5,128 W
Yes
13 current generators fall in the 4,000 W size band. These are the 5 with the most published specs.
Predator, Dual fuel inverter
Predator, Dual fuel inverter
Predator, Open frame
Predator, Open frame
Westinghouse Outdoor Power Equipment, Inverter
One size down: what will a 3,500 watt generator run. One size up: what will a 4,500 watt generator run.
Every appliance's watts are on the appliance wattage chart. To size for your own list, use the calculator.
Yes. A refrigerator is rated at 780 W on the nameplate and sized at 1,200 W to start. On this page a 4,000 watt generator supplies 4,000 W running and 5,128 W starting, so it covers both on its own. Anything else running at the same time adds to the running total.
The biggest air conditioner it runs alone is a central AC (2 ton), sized at 2,472 W running and 4,500 W to start. The next one up, a central AC (3 ton), needs 3,240 W running and 6,000 W to start, more than this size gives. It runs on 240 V, so the generator needs a 240 V outlet.
The biggest well pump it runs alone is a well pump (1 HP), sized at 1,409 W running and 4,000 W to start. That is the largest of the well pumps we list. It runs on 240 V, so the generator needs a 240 V outlet.
About 5,128 W, going by the generators in our data. Across 13 current generators in the 4,000 W size band, the median starting figure is 1.28 times the running figure. Makers print their own starting watts, so check the one you buy against the motor you need to start.