Westinghouse WGen6000DFc EFI
Westinghouse Outdoor Power Equipment, Dual fuel open frame
- Running
- 6,000 W
- Starting
- 7,500 W
- Weight
- 139 lb
An electric dryer is rated 5,600 W on the nameplate, the median of 4 sampled models. Champion's generator chart lists 4,000 to 6,000 W running. Sizing uses 5,600 W to start: its running draw, since no maker or chart prints a surge. The smallest size that covers it alone is 6,000 W.
| Figure | Value | Where it comes from |
|---|---|---|
| Rated draw (nameplate) | 5,600 W | Median of 4 sampled models: printed watts, or printed amps x 240 V. A nameplate figure is a maximum rating. |
| Typical running (generator maker's chart) | 4,000 to 6,000 W | Champion generator wattage chart |
| Starting watts for sizing | 5,600 W | Used because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown. |
| Amps at 240 V | 23.3 A | Rated draw divided by 240 V. |
What was sampled: 7.0 to 7.8 cu ft full-size electric dryers on a 240 V circuit; the heating element is most of the draw.
Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 240 V when the maker prints amps only.
| Printed as, document, checked | |||||
|---|---|---|---|---|---|
| GE | GTD38EASWWS | 24 | 5,600 | 5,600 | Watts, products.geappliances.com, checked |
| GE | GTD58EBSVWS | 24 | 5,600 | 5,600 | Watts, products.geappliances.com, checked |
| GE | GFD55ESSNWW | not published | 5,600 | 5,600 | Watts, products.geappliances.com, checked |
| Frigidaire | FFQE5000QW | 24 | not published | 5,760 | Amps @ 240 Volts, frigidaire.bynder.com, checked |
The smallest listed size that covers 5,600 W running and 5,600 W starting on its own is 6,000 W. It runs on 240 V, so the generator needs a 240 V outlet.
The smallest current generators in our data that run it alone:
Westinghouse Outdoor Power Equipment, Dual fuel open frame
Champion Power Equipment, Dual fuel open frame
Champion Power Equipment, Open frame
Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.
| Question | Generator running W | Generator starting W | Answer |
|---|---|---|---|
| Will a 2,000 watt generator run an electric dryer? | 2,000 | 2,545 | No, too many running watts |
| Will a 3,500 watt generator run an electric dryer? | 3,500 | 4,375 | No, too many running watts |
| Will a 5,000 watt generator run an electric dryer? | 5,000 | 5,500 | No, too many running watts |
| Will a 7,500 watt generator run an electric dryer? | 7,500 | 9,388 | Yes, with a 240 V outlet |
Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.
| Running at once | Running total W | Peak at the largest start W | Runs |
|---|---|---|---|
| Electric dryer | 5,600 | 5,600 | No, too many running watts |
| Electric dryer + LED lights | 5,609 | 5,609 | No, too many running watts |
| Electric dryer + LED lights + phone charger | 5,629 | 5,629 | No, too many running watts |
| Electric dryer + LED lights + phone charger + TV | 5,848 | 5,848 | No, too many running watts |
| Electric dryer + LED lights + phone charger + TV + refrigerator | 6,628 | 7,048 | No, too many running watts |
960 W running 960 W starting
720 W running 2,300 W starting
| Spec | Value | Printed as | Document | Checked |
|---|---|---|---|---|
| GE GTD38EASWWS: rated amps | 24 A | Amps | products.geappliances.com (product page html) | |
| GE GTD38EASWWS: rated watts | 5,600 W | Watts | products.geappliances.com (product page html) | |
| GE GTD58EBSVWS: rated amps | 24 A | Amps | products.geappliances.com (product page html) | |
| GE GTD58EBSVWS: rated watts | 5,600 W | Watts | products.geappliances.com (product page html) | |
| GE GFD55ESSNWW: rated watts | 5,600 W | Watts | products.geappliances.com (product page html) | |
| Frigidaire FFQE5000QW: rated amps | 24 A | Amps @ 240 Volts | frigidaire.bynder.com (spec sheet pdf) |
The 4 models we sampled print a median of 5,600 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 4,000 to 6,000 W as typical running watts. Plan for 5,600 W when it starts.
At 240 V, 5,600 W works out to 23.3 A. That is the median nameplate draw divided by 240 V. An electric dryer draws from a 240 V circuit, so a generator needs a 240 V outlet to run it. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.
The smallest listed size that covers an electric dryer on its own is 6,000 W. That covers 5,600 W running and 5,600 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Westinghouse WGen6000DFc EFI at 6,000 W running.
We size an electric dryer at 5,600 W to start, because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.