How many watts does a well pump (1 HP) use?

A well pump (1 HP) is rated 1,409 W on the nameplate, the median of 4 sampled models. Champion's generator chart lists 1,000 to 2,000 W running. Sizing uses 4,000 W to start: the top of Champion's starting band, as no maker prints one. The smallest size that covers it alone is 3,500 W.

Well pump (1 HP) figures

Well pump (1 HP): draw, starting watts and amps Checked on
Figure Value Where it comes from
Rated draw (nameplate) 1,409 W Median of 4 sampled models: printed watts, or printed amps x 240 V. A nameplate figure is a maximum rating.
Typical running (generator maker's chart) 1,000 to 2,000 W Champion generator wattage chart
Starting (generator maker's chart) 2,000 to 4,000 W Champion generator wattage chart
Inrush (LRA x 240 V) 11,688 W Highest locked rotor amps on the sampled sheets times the voltage. A split-second stalled-rotor figure; not used for sizing.
Starting watts for sizing 4,000 W Used because no sampled maker prints a surge, so it is the top of Champion's starting band.
Amps at 240 V 5.9 A Rated draw divided by 240 V.

What was sampled: 1 HP 4 inch submersible well pump motor, 230 V, 2-wire and 3-wire.

The models we sampled

Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 240 V when the maker prints amps only.

Well pump (1 HP) models sampled Checked on
Printed as, document, checked
Franklin Electric 244508 8.2 1,210 48.7 1,210 Full Load Watts, fele.widen.net, checked
Franklin Electric 214508 8.2 1,210 41.8 1,210 Full Load Watts, fele.widen.net, checked
Pentek (Pentair) P42B0010A2-01 6.7 not published 23.5 1,608 FULL LOAD AMPS, pentair.com, checked
Pentek (Pentair) P43B0010A2-01 8.5 not published 41 2,040 FULL LOAD AMPS, pentair.com, checked

The generator you need

The smallest listed size that covers 1,409 W running and 4,000 W starting on its own is 3,500 W. It runs on 240 V, so the generator needs a 240 V outlet.

The smallest current generators in our data that run it alone:

Add it to the calculator with other appliances

Will a 2,000 to 7,500 watt generator run it?

Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.

Well pump (1 HP) on four generator sizes
Question Generator running W Generator starting W Answer
Will a 2,000 watt generator run a well pump (1 HP)? 2,000 2,545 No, cannot start it
Will a 3,500 watt generator run a well pump (1 HP)? 3,500 4,375 Yes, with a 240 V outlet
Will a 5,000 watt generator run a well pump (1 HP)? 5,000 5,500 Yes, with a 240 V outlet
Will a 7,500 watt generator run a well pump (1 HP)? 7,500 9,388 Yes, with a 240 V outlet

With other appliances on a 3,500 W generator

Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.

Well pump (1 HP) with other appliances on a 3,500 W generator
Running at once Running total W Peak at the largest start W Runs
Well pump (1 HP) 1,409 4,000 Yes, with a 240 V outlet
Well pump (1 HP) + LED lights 1,418 4,009 Yes, with a 240 V outlet
Well pump (1 HP) + LED lights + phone charger 1,438 4,029 Yes, with a 240 V outlet
Well pump (1 HP) + LED lights + phone charger + TV 1,657 4,248 Yes, with a 240 V outlet
Well pump (1 HP) + LED lights + phone charger + TV + refrigerator 2,437 5,028 No, cannot start it

Every appliance on one chart

Sources

Where each Well pump (1 HP) value comes from
Spec Value Printed as Document Checked
Franklin Electric 244508: rated amps 8.2 A Full Load Amps fele.widen.net (owners manual pdf)
Franklin Electric 244508: rated watts 1,210 W Full Load Watts fele.widen.net (owners manual pdf)
Franklin Electric 244508: locked rotor amps 48.7 A Locked Rotor Amps fele.widen.net (owners manual pdf)
Franklin Electric 214508: rated amps 8.2 A Full Load Amps fele.widen.net (owners manual pdf)
Franklin Electric 214508: rated watts 1,210 W Full Load Watts fele.widen.net (owners manual pdf)
Franklin Electric 214508: locked rotor amps 41.8 A Locked Rotor Amps fele.widen.net (owners manual pdf)
Pentek (Pentair) P42B0010A2-01: rated amps 6.7 A FULL LOAD AMPS pentair.com (spec sheet pdf)
Pentek (Pentair) P42B0010A2-01: locked rotor amps 23.5 A LOCKED ROTOR AMPS pentair.com (spec sheet pdf)
Pentek (Pentair) P43B0010A2-01: rated amps 8.5 A FULL LOAD AMPS pentair.com (spec sheet pdf)
Pentek (Pentair) P43B0010A2-01: locked rotor amps 41 A LOCKED ROTOR AMPS pentair.com (spec sheet pdf)

Questions people ask

How many watts does a well pump (1 HP) use?

The 4 models we sampled print a median of 1,409 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 1,000 to 2,000 W as typical running watts. Plan for 4,000 W when it starts.

How many amps does a well pump (1 HP) draw?

At 240 V, 1,409 W works out to 5.9 A. That is the median nameplate draw divided by 240 V. A well pump (1 HP) draws from a 240 V circuit, so a generator needs a 240 V outlet to run it. Locked rotor amps put the split-second inrush near 11,688 W, a figure not used for sizing.

What size generator does a well pump (1 HP) need?

The smallest listed size that covers a well pump (1 HP) on its own is 3,500 W. That covers 1,409 W running and 4,000 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Predator 4375 Portable Generator at 3,500 W running.

How many watts does a well pump (1 HP) need to start?

We size a well pump (1 HP) at 4,000 W to start, because no sampled maker prints a surge, so it is the top of Champion's starting band. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.

Page data checked on