Champion 2500W Dual Fuel Inverter 201530
Champion Power Equipment, Dual fuel inverter
- Running
- 1,850 W
- Starting
- 2,500 W
- Weight
- 43.2 lb
A window AC (12,000 Btu) is rated 1,035 W on the nameplate, the median of 5 sampled models. Champion's generator chart lists 900 to 1,200 W running. Sizing uses 2,400 W to start: the top of Champion's starting band, as no maker prints one. The smallest size that covers it alone is 2,000 W.
| Figure | Value | Where it comes from |
|---|---|---|
| Rated draw (nameplate) | 1,035 W | Median of 5 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating. |
| Typical running (generator maker's chart) | 900 to 1,200 W | Champion generator wattage chart |
| Starting (generator maker's chart) | 1,800 to 2,400 W | Champion generator wattage chart |
| Starting watts for sizing | 2,400 W | Used because no sampled maker prints a surge, so it is the top of Champion's starting band. |
| Amps at 120 V | 8.6 A | Rated draw divided by 120 V. |
| Energy use per year | 600 kWh | Printed on 1 of the 5 sampled models' documents. |
What was sampled: 12,000 Btu window unit, 115 V, cooling mode.
Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.
| Printed as, document, checked | |||||
|---|---|---|---|---|---|
| LG | LW1216ER | 9.3 | 990 | 990 | Watts (Cooling), lg.com, checked |
| LG | LW1217ERSM | 9.3 | 990 | 990 | Watts (Cooling), lg.com, checked |
| GE | AHEK12AC | 9.4 | 1,035 | 1,035 | Cooling - Watts, products.geappliances.com, checked |
| Frigidaire | FHWW122WCE | 10 | 1,100 | 1,100 | Watts (Cool), frigidaire.bynder.com, checked |
| Frigidaire | FHWW125WE1 | 10.3 | 1,150 | 1,150 | Watts (Cool), frigidaire.bynder.com, checked |
The smallest listed size that covers 1,035 W running and 2,400 W starting on its own is 2,000 W.
The smallest current generators in our data that run it alone:
Champion Power Equipment, Dual fuel inverter
RYOBI, Inverter
Westinghouse Outdoor Power Equipment, Dual fuel inverter
Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.
| Question | Generator running W | Generator starting W | Answer |
|---|---|---|---|
| Will a 2,000 watt generator run a window AC (12,000 Btu)? | 2,000 | 2,545 | Yes |
| Will a 3,500 watt generator run a window AC (12,000 Btu)? | 3,500 | 4,375 | Yes |
| Will a 5,000 watt generator run a window AC (12,000 Btu)? | 5,000 | 5,500 | Yes |
| Will a 7,500 watt generator run a window AC (12,000 Btu)? | 7,500 | 9,388 | Yes |
Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.
| Running at once | Running total W | Peak at the largest start W | Runs |
|---|---|---|---|
| Window AC (12,000 Btu) | 1,035 | 2,400 | Yes |
| Window AC (12,000 Btu) + LED lights | 1,044 | 2,409 | Yes |
| Window AC (12,000 Btu) + LED lights + phone charger | 1,064 | 2,429 | Yes |
| Window AC (12,000 Btu) + LED lights + phone charger + TV | 1,283 | 2,648 | Yes |
| Window AC (12,000 Btu) + LED lights + phone charger + TV + refrigerator | 2,063 | 3,428 | Yes |
2,472 W running 4,500 W starting
3,240 W running 6,000 W starting
5,376 W running 8,000 W starting
750 W running 1,600 W starting
3,456 W running 6,000 W starting
445 W running 1,200 W starting
710 W running 2,400 W starting
| Spec | Value | Printed as | Document | Checked |
|---|---|---|---|---|
| LG LW1216ER: rated amps | 9.3 A | Rated Amps (Cooling) | lg.com (spec sheet pdf) | |
| LG LW1216ER: rated watts | 990 W | Watts (Cooling) | lg.com (spec sheet pdf) | |
| LG LW1217ERSM: rated amps | 9.3 A | Rated Amps (Cooling) | lg.com (spec sheet pdf) | |
| LG LW1217ERSM: rated watts | 990 W | Watts (Cooling) | lg.com (spec sheet pdf) | |
| GE AHEK12AC: rated amps | 9.4 A | Cooling - Rated Cooling Amps AHAM | products.geappliances.com (product page html) | |
| GE AHEK12AC: rated watts | 1,035 W | Cooling - Watts | products.geappliances.com (product page html) | |
| Frigidaire FHWW122WCE: rated amps | 10 A | Amps (Cool) | frigidaire.bynder.com (spec sheet pdf) | |
| Frigidaire FHWW122WCE: rated watts | 1,100 W | Watts (Cool) | frigidaire.bynder.com (spec sheet pdf) | |
| Frigidaire FHWW125WE1: rated amps | 10.3 A | Amps (Cool) | frigidaire.bynder.com (spec sheet pdf) | |
| Frigidaire FHWW125WE1: rated watts | 1,150 W | Watts (Cool) | frigidaire.bynder.com (spec sheet pdf) | |
| Frigidaire FHWW125WE1: energy use per year | 600 kWh/yr | annual_energy_use_kwh_yr | data.energystar.gov (energy star api) |
The 5 models we sampled print a median of 1,035 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 900 to 1,200 W as typical running watts. Plan for 2,400 W when it starts.
At 120 V, 1,035 W works out to 8.6 A. That is the median nameplate draw divided by 120 V. A window AC (12,000 Btu) draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.
The smallest listed size that covers a window AC (12,000 Btu) on its own is 2,000 W. That covers 1,035 W running and 2,400 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Champion 2500W Dual Fuel Inverter 201530 at 1,850 W running.
We size a window AC (12,000 Btu) at 2,400 W to start, because no sampled maker prints a surge, so it is the top of Champion's starting band. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.