The two numbers on every generator
Look at any generator spec sheet and you'll see two wattage figures. The Honda EU2200i, for example, is rated at 1,800 W running and 2,200 W starting. The Predator 3500 Super Quiet Inverter Generator is rated at 3,000 W running and 3,500 W starting.
The bigger number gets printed on the box. The smaller one is what you can actually use all day. Makers name these differently: "rated" or "continuous" means running; "maximum," "peak" or "surge" means starting. Model pages on this site show the label exactly as each maker prints it, next to the value.
Why motors need a surge
An electric motor at rest draws far more current for the first moment of starting than it does once it's spinning. A refrigerator compressor, a well pump, a sump pump, an air conditioner, a furnace blower and a power saw all do this. The surge lasts a second or two.
Appliances that only make heat or light don't surge in the same way. A toaster, a space heater, a coffee maker's heating element or an LED bulb draws about the same from the moment it switches on.
On air conditioners and refrigeration equipment, the surge often shows up on the data plate as locked rotor amps (LRA). That's the current the motor pulls before it starts turning. Multiply LRA by the voltage and you have a rough starting-watts figure for that unit.
How to add them up
Utility and manufacturer sizing worksheets use the same method [13]:
- Add the running watts of everything that will run at the same time.
- Find the single item with the highest additional starting watts.
- Add that one surge to the running total. That's your starting requirement.
Then check the generator two ways:
- your running total must fit under its running watts, ideally with headroom (this site sizes to 0.8 of the running rating)
- your running total plus the largest surge must fit under its starting watts
You add only one surge because motors rarely start at the same instant. If two big motors could start together, a well pump and an AC say, add both surges or stagger them.
The calculator does all of this using appliance figures from real manufacturer spec sheets:
Where the appliance numbers come from
There's no official wattage for "a refrigerator." Each appliance page on this site samples several real models and reads the rated amps or watts off each maker's spec sheet. Running watts is the median across those samples. Starting watts is the highest surge any sampled maker publishes, so the estimate leans toward caution.
The table below lists every appliance with both figures:
| Air compressor | Workshop and tools | 1,338 | 1,500 to 2,500 | 7,500 (chart) | 11.2 | 6,000 W |
|---|---|---|---|---|---|---|
| Box fan | Around the house | 96 | 50 to 200 | 96 | 0.8 | 2,000 W |
| Ceiling fan | Around the house | 42 | 15 to 75 | 42 | 0.4 | 2,000 W |
| Central AC (2 ton) | Heating and cooling | 2,472 | 2,000 to 2,500 | 4,500 (chart) | 10.3 A at 240 V | 4,000 W |
| Central AC (3 ton) | Heating and cooling | 3,240 | 3,000 to 3,500 | 6,000 (chart) | 13.5 A at 240 V | 5,500 W |
| Central AC (4 ton) | Heating and cooling | 5,376 | 4,000 to 5,000 | 8,000 (chart) | 22.4 A at 240 V | 6,500 W |
| Circular saw (7-1/4 inch) | Workshop and tools | 1,800 | 1,200 to 1,800 | 3,600 (chart) | 15 | 3,000 W |
| Coffee maker | Kitchen | 938 | 600 to 600 | 938 | 7.8 | 2,000 W |
| CPAP machine | Medical | 172 | 60 to 120 | 172 | 1.4 | 2,000 W |
| Dehumidifier | Around the house | 500 | not published | 500 | 4.2 | 2,000 W |
| Desktop computer | Electronics | 200 | 600 to 800 | 200 | 1.7 | 2,000 W |
| Dishwasher | Kitchen | 1,068 | 1,200 to 2,400 | 1,068 | 8.9 | 2,000 W |
| Electric dryer | Laundry | 5,600 | 4,000 to 6,000 | 5,600 | 23.3 A at 240 V | 6,000 W |
| Electric range | Kitchen | 12,100 | 2,100 to 2,100 | 12,100 | 50.4 A at 240 V | 15,000 W |
| Electric water heater | Water and pumps | 4,500 | 3,000 to 4,500 | 4,500 | 18.8 A at 240 V | 4,500 W |
| EV charger (Level 1) | Around the house | 1,440 | not published | 1,440 | 12 | 2,000 W |
| Freezer | Kitchen | 600 | 100 to 500 | 1,000 (chart) | 5 | 2,000 W |
| Furnace blower | Heating and cooling | 750 | 300 to 800 | 1,600 (chart) | 6.3 | 2,000 W |
| Garage door opener | Around the house | 390 | 720 to 720 | 1,420 (chart) | 3.3 | 2,000 W |
| Gas dryer | Laundry | 960 | not published | 960 | 8 | 2,000 W |
| Hair dryer | Around the house | 1,875 | 1,800 to 1,800 | 1,875 | 15.6 | 2,000 W |
| Heat pump | Heating and cooling | 3,456 | 3,000 to 3,500 | 6,000 (chart) | 14.4 A at 240 V | 5,500 W |
| Hot tub | Water and pumps | 8,880 | not published | 8,880 | 37 A at 240 V | 9,000 W |
| LED lights | Around the house | 9 | 8 to 15 | 9 | 0.1 | 2,000 W |
| Microwave | Kitchen | 1,515 | 1,000 to 1,500 | 1,515 | 12.6 | 2,000 W |
| MIG welder (140 A, 120 V) | Workshop and tools | 2,400 | 1,800 to 2,500 | 5,000 (chart) | 20 | 4,000 W |
| Mini fridge | Kitchen | 130 | 50 to 100 | 600 (chart) | 1.1 | 2,000 W |
| Oxygen concentrator | Medical | 330 | not published | 330 | 2.8 | 2,000 W |
| Phone charger | Electronics | 20 | 20 to 100 | 20 | 0.2 | 2,000 W |
| Refrigerator | Kitchen | 780 | 150 to 400 | 1,200 (chart) | 6.5 | 2,000 W |
| RV air conditioner | RV | 1,596 | 1,500 to 2,500 | 4,500 (chart) | 13.3 | 4,000 W |
| Slow cooker | Kitchen | 290 | 170 to 270 | 290 | 2.4 | 2,000 W |
| Space heater | Around the house | 1,500 | 750 to 1,500 | 1,500 | 12.5 | 2,000 W |
| Starlink | Electronics | 100 | not published | 100 | 0.8 | 2,000 W |
| Sump pump (1/2 HP) | Water and pumps | 936 | 800 to 1,050 | 2,150 (chart) | 7.8 | 2,000 W |
| Sump pump (1/3 HP) | Water and pumps | 624 | 500 to 800 | 1,600 (chart) | 5.2 | 2,000 W |
| Table saw (10 inch) | Workshop and tools | 1,800 | 1,800 to 3,000 | 6,000 (chart) | 15 | 5,500 W |
| Toaster oven | Kitchen | 1,500 | not published | 1,500 | 12.5 | 2,000 W |
| TV | Electronics | 219 | 80 to 400 | 219 | 1.8 | 2,000 W |
| Washing machine | Laundry | 720 | 500 to 1,000 | 2,300 (chart) | 6 | 2,000 W |
| Well pump (1 HP) | Water and pumps | 1,409 | 1,000 to 2,000 | 4,000 (chart) | 5.9 A at 240 V | 3,500 W |
| Well pump (1/2 HP) | Water and pumps | 851 | 750 to 1,000 | 2,000 (chart) | 3.5 A at 240 V | 3,500 W |
| Wi-Fi router | Electronics | 7 | 10 to 20 | 7 | 0.1 | 2,000 W |
| Window AC (12,000 Btu) | Heating and cooling | 1,035 | 900 to 1,200 | 2,400 (chart) | 8.6 | 2,000 W |
| Window AC (5,000 Btu) | Heating and cooling | 445 | 450 to 600 | 1,200 (chart) | 3.7 | 2,000 W |
| Window AC (8,000 Btu) | Heating and cooling | 710 | 900 to 1,200 | 2,400 (chart) | 5.9 | 2,000 W |
Where no sampled maker prints a starting figure for a motor appliance, the page says so and shows the range from a generator maker's wattage chart instead, with that chart linked.
The usual ways people get caught
Sizing from the box number. A generator sold on its starting watts will stall or trip if you try to run that much continuously. Size from the running watts.
Forgetting the surge. Everything runs fine until the fridge compressor kicks on while the microwave is going, and the generator breaker trips. Check your running load plus the biggest surge.
Two motors at once. After an outage, the fridge, freezer and well pump may all try to start the moment power comes back. Turn their breakers or plugs on one at a time, a few seconds apart.
Altitude and heat. Engines lose output in thin air and high temperatures. Check the owner's manual for derating if you're well above sea level.
Power stations surge differently
A battery power station has an inverter rather than an engine. It publishes a continuous output and a surge or peak figure, and how long it holds the peak varies by maker. A small station may run a fridge but fail to start a well pump. The power station vs gas generator guide covers this.
A worked check
Say your list is a refrigerator, a furnace blower, lights, a TV and the router. Add their running watts from the appliance table. The largest surge on that list is usually the fridge compressor or the furnace blower motor, whichever the table shows higher. Add that one surge. Compare the running total with a generator's running watts and the starting total with its starting watts.
The size pages do this for every appliance at each generator size, so you can see which combinations fit a 3500 watt, 5000 watt or 7500 watt unit.
FAQ
What's the difference between running watts and starting watts?
Running watts is the power a generator can supply continuously. Starting watts is the higher figure it can supply for a few seconds to start a motor. Your total running load has to fit under the first, and your running load plus the biggest motor surge has to fit under the second.
Do I add starting watts for every appliance?
No. Add the running watts for everything, then add only the single largest starting surge. Motors rarely start at the same instant, so one surge on top of the running total is the standard sizing method. If two large motors may start together, stagger them or add both surges.
Which number should I use to size a generator?
Both. The running watts must cover everything running at once with headroom, and the starting watts must cover that plus the biggest surge. Most sizing mistakes come from comparing the appliance list with the generator's starting figure, which it can't sustain.
Does a refrigerator need starting watts?
Yes. A refrigerator has a compressor motor, so it surges each time the compressor starts, not just when you first plug it in. The refrigerator page shows the surge figure from sampled makers' spec sheets, or the chart range when no sampled maker publishes one.