Running watts vs starting watts

Running watts is the power a generator can supply continuously. Starting watts, also called surge or peak watts, is the extra it can deliver for a few seconds while a motor starts. Size so your total running load fits the running rating, and your running load plus the largest motor surge fits the starting rating.

Updated

The two numbers on every generator

Look at any generator spec sheet and you'll see two wattage figures. The Honda EU2200i, for example, is rated at 1,800 W running and 2,200 W starting. The Predator 3500 Super Quiet Inverter Generator is rated at 3,000 W running and 3,500 W starting.

The bigger number gets printed on the box. The smaller one is what you can actually use all day. Makers name these differently: "rated" or "continuous" means running; "maximum," "peak" or "surge" means starting. Model pages on this site show the label exactly as each maker prints it, next to the value.

Why motors need a surge

An electric motor at rest draws far more current for the first moment of starting than it does once it's spinning. A refrigerator compressor, a well pump, a sump pump, an air conditioner, a furnace blower and a power saw all do this. The surge lasts a second or two.

Appliances that only make heat or light don't surge in the same way. A toaster, a space heater, a coffee maker's heating element or an LED bulb draws about the same from the moment it switches on.

On air conditioners and refrigeration equipment, the surge often shows up on the data plate as locked rotor amps (LRA). That's the current the motor pulls before it starts turning. Multiply LRA by the voltage and you have a rough starting-watts figure for that unit.

How to add them up

Utility and manufacturer sizing worksheets use the same method [13]:

  1. Add the running watts of everything that will run at the same time.
  2. Find the single item with the highest additional starting watts.
  3. Add that one surge to the running total. That's your starting requirement.

Then check the generator two ways:

  • your running total must fit under its running watts, ideally with headroom (this site sizes to 0.8 of the running rating)
  • your running total plus the largest surge must fit under its starting watts

You add only one surge because motors rarely start at the same instant. If two big motors could start together, a well pump and an AC say, add both surges or stagger them.

The calculator does all of this using appliance figures from real manufacturer spec sheets:

Example: a refrigerator, LED lights, a phone charger and a TV
Appliance RunningW Starting for sizingW
Refrigerator 780 W 1,200 W (chart)
LED lights 9 W 9 W
Phone charger 20 W 20 W
TV 219 W 219 W
Running total
1,028 W
Starting peak
1,448 W
Recommended size
2,000 W

The running total divided by the continuous-load factor of 0.8 is 1,285 W. The starting peak is the running total plus the largest single surge. The larger of the two, rounded up to the next listed size, is the recommendation. Starting watts for Refrigerator come from the generator maker's chart, because the sampled spec sheets print no surge figure.

Size your own list in the calculator

Where the appliance numbers come from

There's no official wattage for "a refrigerator." Each appliance page on this site samples several real models and reads the rated amps or watts off each maker's spec sheet. Running watts is the median across those samples. Starting watts is the highest surge any sampled maker publishes, so the estimate leans toward caution.

The table below lists every appliance with both figures:

Appliance wattage from sampled spec sheets Checked on
Air compressor Workshop and tools 1,338 1,500 to 2,500 7,500 (chart) 11.2 6,000 W
Box fan Around the house 96 50 to 200 96 0.8 2,000 W
Ceiling fan Around the house 42 15 to 75 42 0.4 2,000 W
Central AC (2 ton) Heating and cooling 2,472 2,000 to 2,500 4,500 (chart) 10.3 A at 240 V 4,000 W
Central AC (3 ton) Heating and cooling 3,240 3,000 to 3,500 6,000 (chart) 13.5 A at 240 V 5,500 W
Central AC (4 ton) Heating and cooling 5,376 4,000 to 5,000 8,000 (chart) 22.4 A at 240 V 6,500 W
Circular saw (7-1/4 inch) Workshop and tools 1,800 1,200 to 1,800 3,600 (chart) 15 3,000 W
Coffee maker Kitchen 938 600 to 600 938 7.8 2,000 W
CPAP machine Medical 172 60 to 120 172 1.4 2,000 W
Dehumidifier Around the house 500 not published 500 4.2 2,000 W
Desktop computer Electronics 200 600 to 800 200 1.7 2,000 W
Dishwasher Kitchen 1,068 1,200 to 2,400 1,068 8.9 2,000 W
Electric dryer Laundry 5,600 4,000 to 6,000 5,600 23.3 A at 240 V 6,000 W
Electric range Kitchen 12,100 2,100 to 2,100 12,100 50.4 A at 240 V 15,000 W
Electric water heater Water and pumps 4,500 3,000 to 4,500 4,500 18.8 A at 240 V 4,500 W
EV charger (Level 1) Around the house 1,440 not published 1,440 12 2,000 W
Freezer Kitchen 600 100 to 500 1,000 (chart) 5 2,000 W
Furnace blower Heating and cooling 750 300 to 800 1,600 (chart) 6.3 2,000 W
Garage door opener Around the house 390 720 to 720 1,420 (chart) 3.3 2,000 W
Gas dryer Laundry 960 not published 960 8 2,000 W
Hair dryer Around the house 1,875 1,800 to 1,800 1,875 15.6 2,000 W
Heat pump Heating and cooling 3,456 3,000 to 3,500 6,000 (chart) 14.4 A at 240 V 5,500 W
Hot tub Water and pumps 8,880 not published 8,880 37 A at 240 V 9,000 W
LED lights Around the house 9 8 to 15 9 0.1 2,000 W
Microwave Kitchen 1,515 1,000 to 1,500 1,515 12.6 2,000 W
MIG welder (140 A, 120 V) Workshop and tools 2,400 1,800 to 2,500 5,000 (chart) 20 4,000 W
Mini fridge Kitchen 130 50 to 100 600 (chart) 1.1 2,000 W
Oxygen concentrator Medical 330 not published 330 2.8 2,000 W
Phone charger Electronics 20 20 to 100 20 0.2 2,000 W
Refrigerator Kitchen 780 150 to 400 1,200 (chart) 6.5 2,000 W
RV air conditioner RV 1,596 1,500 to 2,500 4,500 (chart) 13.3 4,000 W
Slow cooker Kitchen 290 170 to 270 290 2.4 2,000 W
Space heater Around the house 1,500 750 to 1,500 1,500 12.5 2,000 W
Starlink Electronics 100 not published 100 0.8 2,000 W
Sump pump (1/2 HP) Water and pumps 936 800 to 1,050 2,150 (chart) 7.8 2,000 W
Sump pump (1/3 HP) Water and pumps 624 500 to 800 1,600 (chart) 5.2 2,000 W
Table saw (10 inch) Workshop and tools 1,800 1,800 to 3,000 6,000 (chart) 15 5,500 W
Toaster oven Kitchen 1,500 not published 1,500 12.5 2,000 W
TV Electronics 219 80 to 400 219 1.8 2,000 W
Washing machine Laundry 720 500 to 1,000 2,300 (chart) 6 2,000 W
Well pump (1 HP) Water and pumps 1,409 1,000 to 2,000 4,000 (chart) 5.9 A at 240 V 3,500 W
Well pump (1/2 HP) Water and pumps 851 750 to 1,000 2,000 (chart) 3.5 A at 240 V 3,500 W
Wi-Fi router Electronics 7 10 to 20 7 0.1 2,000 W
Window AC (12,000 Btu) Heating and cooling 1,035 900 to 1,200 2,400 (chart) 8.6 2,000 W
Window AC (5,000 Btu) Heating and cooling 445 450 to 600 1,200 (chart) 3.7 2,000 W
Window AC (8,000 Btu) Heating and cooling 710 900 to 1,200 2,400 (chart) 5.9 2,000 W

Where no sampled maker prints a starting figure for a motor appliance, the page says so and shows the range from a generator maker's wattage chart instead, with that chart linked.

The usual ways people get caught

Sizing from the box number. A generator sold on its starting watts will stall or trip if you try to run that much continuously. Size from the running watts.

Forgetting the surge. Everything runs fine until the fridge compressor kicks on while the microwave is going, and the generator breaker trips. Check your running load plus the biggest surge.

Two motors at once. After an outage, the fridge, freezer and well pump may all try to start the moment power comes back. Turn their breakers or plugs on one at a time, a few seconds apart.

Altitude and heat. Engines lose output in thin air and high temperatures. Check the owner's manual for derating if you're well above sea level.

Power stations surge differently

A battery power station has an inverter rather than an engine. It publishes a continuous output and a surge or peak figure, and how long it holds the peak varies by maker. A small station may run a fridge but fail to start a well pump. The power station vs gas generator guide covers this.

A worked check

Say your list is a refrigerator, a furnace blower, lights, a TV and the router. Add their running watts from the appliance table. The largest surge on that list is usually the fridge compressor or the furnace blower motor, whichever the table shows higher. Add that one surge. Compare the running total with a generator's running watts and the starting total with its starting watts.

The size pages do this for every appliance at each generator size, so you can see which combinations fit a 3500 watt, 5000 watt or 7500 watt unit.

FAQ

What's the difference between running watts and starting watts?

Running watts is the power a generator can supply continuously. Starting watts is the higher figure it can supply for a few seconds to start a motor. Your total running load has to fit under the first, and your running load plus the biggest motor surge has to fit under the second.

Do I add starting watts for every appliance?

No. Add the running watts for everything, then add only the single largest starting surge. Motors rarely start at the same instant, so one surge on top of the running total is the standard sizing method. If two large motors may start together, stagger them or add both surges.

Which number should I use to size a generator?

Both. The running watts must cover everything running at once with headroom, and the starting watts must cover that plus the biggest surge. Most sizing mistakes come from comparing the appliance list with the generator's starting figure, which it can't sustain.

Does a refrigerator need starting watts?

Yes. A refrigerator has a compressor motor, so it surges each time the compressor starts, not just when you first plug it in. The refrigerator page shows the surge figure from sampled makers' spec sheets, or the chart range when no sampled maker publishes one.

Page data checked on