How many watts does an oxygen concentrator use?

An oxygen concentrator is rated 330 W on the nameplate, the median of 4 sampled models. No generator maker's chart lists this appliance. Sizing uses 330 W to start: its running draw, since no maker or chart prints a surge. The smallest size that covers it alone is 2,000 W.

Oxygen concentrator figures

Oxygen concentrator: draw, starting watts and amps Checked on
Figure Value Where it comes from
Rated draw (nameplate) 330 W Median of 4 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating.
Typical running (generator maker's chart) not listed No generator maker's chart lists this appliance.
Starting watts for sizing 330 W Used because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown.
Amps at 120 V 2.8 A Rated draw divided by 120 V.

What was sampled: 5-liter stationary home oxygen concentrators on 120 V household power, with a compressor that runs continuously.

The models we sampled

Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.

Oxygen concentrator models sampled Checked on
Printed as, document, checked
Philips Respironics EverFlo 1020000 not published 350 350 Electrical, AC Power Consumption, documents.philips.com, checked
Inogen Inogen At Home GS-100 not published 275 275 Power, inogen.com, checked
Drive DeVilbiss DeVilbiss 525DS 3.3 310 310 Power Consumption, drivedevilbiss.com, checked
CAIRE Companion 5 not published 350 350 Power Consumption, files.caireinc.com, checked

The generator you need

The smallest listed size that covers 330 W running and 330 W starting on its own is 2,000 W.

The smallest current generators in our data that run it alone:

Add it to the calculator with other appliances

Will a 2,000 to 7,500 watt generator run it?

Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.

Oxygen concentrator on four generator sizes
Question Generator running W Generator starting W Answer
Will a 2,000 watt generator run an oxygen concentrator? 2,000 2,545 Yes
Will a 3,500 watt generator run an oxygen concentrator? 3,500 4,375 Yes
Will a 5,000 watt generator run an oxygen concentrator? 5,000 5,500 Yes
Will a 7,500 watt generator run an oxygen concentrator? 7,500 9,388 Yes

With other appliances on a 3,500 W generator

Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.

Oxygen concentrator with other appliances on a 3,500 W generator
Running at once Running total W Peak at the largest start W Runs
Oxygen concentrator 330 330 Yes
Oxygen concentrator + LED lights 339 339 Yes
Oxygen concentrator + LED lights + phone charger 359 359 Yes
Oxygen concentrator + LED lights + phone charger + TV 578 578 Yes
Oxygen concentrator + LED lights + phone charger + TV + refrigerator 1,358 1,778 Yes

Every appliance on one chart

Sources

Where each Oxygen concentrator value comes from
Spec Value Printed as Document Checked
Philips Respironics EverFlo 1020000: rated watts 350 W Electrical, AC Power Consumption documents.philips.com (owners manual pdf)
Inogen Inogen At Home GS-100: rated watts 275 W Power inogen.com (owners manual pdf)
Drive DeVilbiss DeVilbiss 525DS: rated amps 3.3 A Electrical Rating drivedevilbiss.com (owners manual pdf)
Drive DeVilbiss DeVilbiss 525DS: rated watts 310 W Power Consumption drivedevilbiss.com (owners manual pdf)
CAIRE Companion 5: rated watts 350 W Power Consumption files.caireinc.com (owners manual pdf)

Questions people ask

How many watts does an oxygen concentrator use?

The 4 models we sampled print a median of 330 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. No generator maker's chart lists this appliance. Plan for 330 W when it starts.

How many amps does an oxygen concentrator draw?

At 120 V, 330 W works out to 2.8 A. That is the median nameplate draw divided by 120 V. An oxygen concentrator draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.

What size generator does an oxygen concentrator need?

The smallest listed size that covers an oxygen concentrator on its own is 2,000 W. That covers 330 W running and 330 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Honda EU1000i at 900 W running.

How many watts does an oxygen concentrator need to start?

We size an oxygen concentrator at 330 W to start, because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.

Page data checked on