A space heater is rated 1,500 W on the nameplate, the median of 4 sampled models. Champion's generator chart lists 750 to 1,500 W running. Sizing uses 1,500 W to start: its running draw, since it has no motor to start. The smallest size that covers it alone is 2,000 W.
| Figure | Value | Where it comes from |
|---|---|---|
| Rated draw (nameplate) | 1,500 W | Median of 4 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating. |
| Typical running (generator maker's chart) | 750 to 1,500 W | Champion generator wattage chart |
| Starting watts for sizing | 1,500 W | Used because it has no motor to start, so it is the running draw. |
| Amps at 120 V | 12.5 A | Rated draw divided by 120 V. |
What was sampled: 1,500 W plug-in ceramic and infrared portable heaters on the high setting.
Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.
| Printed as, document, checked | |||||
|---|---|---|---|---|---|
| Lasko | 755320 | 12.5 | 1,500 | 1,500 | Energy Output, lasko.com, checked |
| Lasko | 754201 | 12.5 | 1,500 | 1,500 | Energy Output, lasko.com, checked |
| Dr. Infrared Heater | DR-968 | 12.5 | 1,500 | 1,500 | Power, cdn.shopify.com, checked |
| Dr. Infrared Heater | DR-999 | 12.5 | 1,500 | 1,500 | Power, cdn.shopify.com, checked |
The smallest listed size that covers 1,500 W running and 1,500 W starting on its own is 2,000 W.
The smallest current generators in our data that run it alone:
Honda Power Equipment, Inverter
Honda Power Equipment, Inverter
Honda Power Equipment, Inverter
Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.
| Question | Generator running W | Generator starting W | Answer |
|---|---|---|---|
| Will a 2,000 watt generator run a space heater? | 2,000 | 2,545 | Yes |
| Will a 3,500 watt generator run a space heater? | 3,500 | 4,375 | Yes |
| Will a 5,000 watt generator run a space heater? | 5,000 | 5,500 | Yes |
| Will a 7,500 watt generator run a space heater? | 7,500 | 9,388 | Yes |
Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.
| Running at once | Running total W | Peak at the largest start W | Runs |
|---|---|---|---|
| Space heater | 1,500 | 1,500 | Yes |
| Space heater + LED lights | 1,509 | 1,509 | Yes |
| Space heater + LED lights + phone charger | 1,529 | 1,529 | Yes |
| Space heater + LED lights + phone charger + TV | 1,748 | 1,748 | Yes |
| Space heater + LED lights + phone charger + TV + refrigerator | 2,528 | 2,948 | Yes |
96 W running 96 W starting
42 W running 42 W starting
500 W running 500 W starting
1,440 W running 1,440 W starting
390 W running 1,420 W starting
1,875 W running 1,875 W starting
9 W running 9 W starting
| Spec | Value | Printed as | Document | Checked |
|---|---|---|---|---|
| Lasko 755320: rated amps | 12.5 A | Current | lasko.com (product page html) | |
| Lasko 755320: rated watts | 1,500 W | Energy Output | lasko.com (product page html) | |
| Lasko 754201: rated amps | 12.5 A | Current | lasko.com (product page html) | |
| Lasko 754201: rated watts | 1,500 W | Energy Output | lasko.com (product page html) | |
| Dr. Infrared Heater DR-968: rated amps | 12.5 A | Current: Maximum continuous draw | cdn.shopify.com (owners manual pdf) | |
| Dr. Infrared Heater DR-968: rated watts | 1,500 W | Power | cdn.shopify.com (owners manual pdf) | |
| Dr. Infrared Heater DR-999: rated amps | 12.5 A | Current: Maximum continuous draw | cdn.shopify.com (owners manual pdf) | |
| Dr. Infrared Heater DR-999: rated watts | 1,500 W | Power | cdn.shopify.com (owners manual pdf) |
The 4 models we sampled print a median of 1,500 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 750 to 1,500 W as typical running watts. Plan for 1,500 W when it starts.
At 120 V, 1,500 W works out to 12.5 A. That is the median nameplate draw divided by 120 V. A space heater draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.
The smallest listed size that covers a space heater on its own is 2,000 W. That covers 1,500 W running and 1,500 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Honda EB2200i at 1,800 W running.
We size a space heater at 1,500 W to start, because it has no motor to start, so it is the running draw. A generator has to cover that starting figure for a moment and the running figure after. Without a motor, the draw is about the same from the moment it switches on.