How many watts does it take to run a house?

How many watts a house needs is the total draw of everything running at the same moment, plus the surge when a motor starts. That peak, in watts, is what a generator has to cover. Your electric bill shows energy over a month in kilowatt-hours, which is a different number and can't size a generator on its own.

Updated

Example: a refrigerator, LED lights, a phone charger and a TV
Appliance RunningW Starting for sizingW
Refrigerator 780 W 1,200 W (chart)
LED lights 9 W 9 W
Phone charger 20 W 20 W
TV 219 W 219 W
Running total
1,028 W
Starting peak
1,448 W
Recommended size
2,000 W

The running total divided by the continuous-load factor of 0.8 is 1,285 W. The starting peak is the running total plus the largest single surge. The larger of the two, rounded up to the next listed size, is the recommendation. Starting watts for Refrigerator come from the generator maker's chart, because the sampled spec sheets print no surge figure.

Size your own list in the calculator

Watts and kilowatt-hours are different questions

A watt is a rate: how much power something pulls right now. A kilowatt-hour (kWh) is an amount: 1,000 watts for one hour. Your bill counts kWh because the utility charges for energy used over the month.

A generator cares about the rate. It has a ceiling on how many watts it can supply at once, and if the appliances running together go over that ceiling, the breaker trips or the engine bogs down. It doesn't matter how few kWh the house uses over a day if a well pump, a fridge and a microwave all pull at the same moment.

So dividing your monthly kWh by the hours in a month gives an average draw, and the average is always far below the peak. Size from the average and the generator stalls the first time the furnace blower and the fridge compressor start together.

Add up the peak yourself

The method is the same one utility sizing worksheets use [13]:

  1. List what has to run at the same time during an outage.
  2. Look up each item's running watts.
  3. Add them.
  4. Add the single largest starting surge from any motor on the list.

The calculator above does this with figures read from real manufacturers' spec sheets. You can also work from the table below, which lists running and starting watts for every appliance on the site.

Appliance wattage from sampled spec sheets Checked on
Air compressor Workshop and tools 1,338 1,500 to 2,500 7,500 (chart) 11.2 6,000 W
Box fan Around the house 96 50 to 200 96 0.8 2,000 W
Ceiling fan Around the house 42 15 to 75 42 0.4 2,000 W
Central AC (2 ton) Heating and cooling 2,472 2,000 to 2,500 4,500 (chart) 10.3 A at 240 V 4,000 W
Central AC (3 ton) Heating and cooling 3,240 3,000 to 3,500 6,000 (chart) 13.5 A at 240 V 5,500 W
Central AC (4 ton) Heating and cooling 5,376 4,000 to 5,000 8,000 (chart) 22.4 A at 240 V 6,500 W
Circular saw (7-1/4 inch) Workshop and tools 1,800 1,200 to 1,800 3,600 (chart) 15 3,000 W
Coffee maker Kitchen 938 600 to 600 938 7.8 2,000 W
CPAP machine Medical 172 60 to 120 172 1.4 2,000 W
Dehumidifier Around the house 500 not published 500 4.2 2,000 W
Desktop computer Electronics 200 600 to 800 200 1.7 2,000 W
Dishwasher Kitchen 1,068 1,200 to 2,400 1,068 8.9 2,000 W
Electric dryer Laundry 5,600 4,000 to 6,000 5,600 23.3 A at 240 V 6,000 W
Electric range Kitchen 12,100 2,100 to 2,100 12,100 50.4 A at 240 V 15,000 W
Electric water heater Water and pumps 4,500 3,000 to 4,500 4,500 18.8 A at 240 V 4,500 W
EV charger (Level 1) Around the house 1,440 not published 1,440 12 2,000 W
Freezer Kitchen 600 100 to 500 1,000 (chart) 5 2,000 W
Furnace blower Heating and cooling 750 300 to 800 1,600 (chart) 6.3 2,000 W
Garage door opener Around the house 390 720 to 720 1,420 (chart) 3.3 2,000 W
Gas dryer Laundry 960 not published 960 8 2,000 W
Hair dryer Around the house 1,875 1,800 to 1,800 1,875 15.6 2,000 W
Heat pump Heating and cooling 3,456 3,000 to 3,500 6,000 (chart) 14.4 A at 240 V 5,500 W
Hot tub Water and pumps 8,880 not published 8,880 37 A at 240 V 9,000 W
LED lights Around the house 9 8 to 15 9 0.1 2,000 W
Microwave Kitchen 1,515 1,000 to 1,500 1,515 12.6 2,000 W
MIG welder (140 A, 120 V) Workshop and tools 2,400 1,800 to 2,500 5,000 (chart) 20 4,000 W
Mini fridge Kitchen 130 50 to 100 600 (chart) 1.1 2,000 W
Oxygen concentrator Medical 330 not published 330 2.8 2,000 W
Phone charger Electronics 20 20 to 100 20 0.2 2,000 W
Refrigerator Kitchen 780 150 to 400 1,200 (chart) 6.5 2,000 W
RV air conditioner RV 1,596 1,500 to 2,500 4,500 (chart) 13.3 4,000 W
Slow cooker Kitchen 290 170 to 270 290 2.4 2,000 W
Space heater Around the house 1,500 750 to 1,500 1,500 12.5 2,000 W
Starlink Electronics 100 not published 100 0.8 2,000 W
Sump pump (1/2 HP) Water and pumps 936 800 to 1,050 2,150 (chart) 7.8 2,000 W
Sump pump (1/3 HP) Water and pumps 624 500 to 800 1,600 (chart) 5.2 2,000 W
Table saw (10 inch) Workshop and tools 1,800 1,800 to 3,000 6,000 (chart) 15 5,500 W
Toaster oven Kitchen 1,500 not published 1,500 12.5 2,000 W
TV Electronics 219 80 to 400 219 1.8 2,000 W
Washing machine Laundry 720 500 to 1,000 2,300 (chart) 6 2,000 W
Well pump (1 HP) Water and pumps 1,409 1,000 to 2,000 4,000 (chart) 5.9 A at 240 V 3,500 W
Well pump (1/2 HP) Water and pumps 851 750 to 1,000 2,000 (chart) 3.5 A at 240 V 3,500 W
Wi-Fi router Electronics 7 10 to 20 7 0.1 2,000 W
Window AC (12,000 Btu) Heating and cooling 1,035 900 to 1,200 2,400 (chart) 8.6 2,000 W
Window AC (5,000 Btu) Heating and cooling 445 450 to 600 1,200 (chart) 3.7 2,000 W
Window AC (8,000 Btu) Heating and cooling 710 900 to 1,200 2,400 (chart) 5.9 2,000 W

Running watts on an appliance page are the median of the sampled models. Starting watts are the highest surge figure any sampled maker publishes, so the estimate leans safe. Each page links the spec sheets it used.

Where the watts go in a typical house

A few appliances dominate any list. They fall into two groups.

Big resistive loads. An electric water heater, an electric range, an electric dryer, a space heater and a hot tub turn electricity straight into heat. They draw a lot and run steadily, with no starting surge. Most of them are 240 V.

Motor loads. A refrigerator, a freezer, a furnace blower, a sump pump, a well pump and any air conditioner run modestly but surge when the motor starts. The surge sets the starting-watt requirement, and with a well pump or central air it can be the deciding number.

Everything else (lights, the Wi-Fi router, phone chargers, a TV) adds up to less than people expect. LED lighting in particular barely registers next to a fridge.

Three ways to answer "how many watts"

Essentials. Fridge, freezer, lights, router, chargers, TV, maybe a microwave in turns. This is the smallest honest answer and the one most portable generators are bought for.

Essentials plus heat and water. Add a furnace blower, a sump pump or a well pump. Running watts rise a little; starting watts rise a lot because of the pump.

Everything at once. Central air, the water heater, the range and the dryer all on. This number is large enough that it usually points to a standby generator sized by an electrician. The standby sizing guide explains how they calculate it.

The size chart turns each of these into a recommended generator size:

What each generator size runs on its own Checked on
Generator size Starting assumed W Starting basis Runs alone, of 46 Biggest motor it starts
2,000 W 2,545 median ratio 1.27 over 17 models 31 Window AC (12,000 Btu) (2,400 W)
2,500 W 3,077 median ratio 1.23 over 3 models 31 Window AC (12,000 Btu) (2,400 W)
3,000 W 3,750 median ratio 1.25 over 10 models 32 Circular saw (7-1/4 inch) (3,600 W)
3,500 W 4,375 median ratio 1.25 over 18 models 34 Well pump (1 HP) (4,000 W)
4,000 W 5,128 median ratio 1.28 over 13 models 37 MIG welder (140 A, 120 V) (5,000 W)
4,500 W 5,000 median ratio 1.11 over 2 models 38 MIG welder (140 A, 120 V) (5,000 W)
5,000 W 5,500 median ratio 1.1 over 1 model 38 MIG welder (140 A, 120 V) (5,000 W)
5,500 W 6,849 median ratio 1.25 over 15 models 41 Central AC (3 ton) (6,000 W)
6,000 W 7,500 median ratio 1.25 over 1 model 43 Air compressor (7,500 W)
6,500 W 8,125 median ratio 1.25 over 7 models 44 Central AC (4 ton) (8,000 W)
7,000 W 8,750 median ratio 1.25 over 3 models 44 Central AC (4 ton) (8,000 W)
7,500 W 9,388 median ratio 1.25 over 12 models 44 Central AC (4 ton) (8,000 W)
8,000 W 10,000 median ratio 1.25 over 6 models 44 Central AC (4 ton) (8,000 W)
9,000 W 11,500 median ratio 1.28 over 5 models 45 Central AC (4 ton) (8,000 W)
10,000 W 13,158 median ratio 1.32 over 13 models 45 Central AC (4 ton) (8,000 W)
12,000 W 15,130 median ratio 1.26 over 3 models 45 Central AC (4 ton) (8,000 W)
15,000 W 18,621 median ratio 1.24 over 6 models 46 Central AC (4 ton) (8,000 W)

Running watts are the size itself. Starting watts are the size times the median starting-to-running ratio of the current generators in that size that publish both figures. An appliance counts when its running watts and its starting watts for sizing both fit. A 240 V appliance also needs a 240 V outlet, so it counts only when a current generator of that size in our data has one.

Using your panel and bills as a cross-check

Your bills still help in one way: a house with a high winter kWh total probably has electric heat, and that changes the answer. Look at the panel too. Double-pole breakers (the wide ones) feed 240 V loads, and each one is a candidate for a big draw. Write down what each feeds.

The main breaker rating, such as 200 A, is the maximum the panel can carry. It isn't what the house actually pulls. The 200 amp service guide covers why sizing a generator to the main breaker overshoots.

When the answer is "less than you think"

Plenty of people buy a large portable generator, then find their essentials fit on something much smaller once they add it up. If the list is fridge, freezer, lights and chargers, look at what a 3500 watt generator will run before buying bigger. A smaller unit burns less fuel per hour and is easier to move.

If you'd rather avoid fuel entirely, a battery power station can carry a fridge and electronics for a while. Its capacity is measured in watt-hours, so runtime depends on the load. The power station vs gas generator guide works through that trade.

FAQ

How many watts does an average house use?

There's no useful single figure, because it depends on what runs at once. A house on gas heat with a fridge and lights draws a small fraction of what a house running central air, an electric water heater and a dryer pulls. Add up your own list in the calculator to get your peak.

Can I use my electric bill to size a generator?

Not on its own. The bill shows kilowatt-hours over a month, which averages out every peak. A generator has to handle the moment when several appliances and a motor surge happen together. Use the bill to spot electric heat or other big loads, then size from your appliance list.

How many watts does a house need during a power outage?

Only as many as the appliances you choose to run. Most outage plans cover the fridge, freezer, lights, chargers, the router and a furnace blower or sump pump. Add those running watts, add the biggest starting surge, and the calculator recommends a size with headroom.

Is a 200 amp panel the same as needing a 200 amp generator?

No. The main breaker rating is the most the panel can safely carry, not what the house draws. Most homes pull a fraction of it even at peak. An electrician sizes standby generators with a load calculation under the electrical code, not from the main breaker number.