Honda EU1000i
Honda Power Equipment, Inverter
- Running
- 900 W
- Starting
- 1,000 W
- Weight
- 28.7 lb
A CPAP machine is rated 172 W on the nameplate, the median of 4 sampled models. Champion's generator chart lists 60 to 120 W running. Sizing uses 172 W to start: its running draw, since it has no motor to start. The smallest size that covers it alone is 2,000 W.
| Figure | Value | Where it comes from |
|---|---|---|
| Rated draw (nameplate) | 172 W | Median of 4 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating. |
| Typical running (generator maker's chart) | 60 to 120 W | Champion generator wattage chart |
| Starting watts for sizing | 172 W | Used because it has no motor to start, so it is the running draw. |
| Amps at 120 V | 1.4 A | Rated draw divided by 120 V. |
What was sampled: Bedside CPAP and auto CPAP machines with heated humidifier, run from their AC power supply. Electronics with a small blower; no maker prints a starting surge, so motorLoad is false.
Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.
| Printed as, document, checked | |||||
|---|---|---|---|---|---|
| ResMed | AirSense 11 | not published | 73 | 73 | Peak power consumption, document.resmed.com, checked |
| ResMed | AirSense 10 | not published | 104 | 104 | Peak power consumption, document.resmed.com, checked |
| Philips Respironics | DreamStation 2 Advanced | 2 | not published | 240 | Electrical: AC Power Consumption, philips.com, checked |
| React Health | Luna G3 CPAP LG3500 | 2 | not published | 240 | AC Power Consumption, reacthealth.com, checked |
The smallest listed size that covers 172 W running and 172 W starting on its own is 2,000 W.
The smallest current generators in our data that run it alone:
Honda Power Equipment, Inverter
Honda Power Equipment, Inverter
Westinghouse Outdoor Power Equipment, Inverter
Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.
| Question | Generator running W | Generator starting W | Answer |
|---|---|---|---|
| Will a 2,000 watt generator run a CPAP machine? | 2,000 | 2,545 | Yes |
| Will a 3,500 watt generator run a CPAP machine? | 3,500 | 4,375 | Yes |
| Will a 5,000 watt generator run a CPAP machine? | 5,000 | 5,500 | Yes |
| Will a 7,500 watt generator run a CPAP machine? | 7,500 | 9,388 | Yes |
Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.
| Running at once | Running total W | Peak at the largest start W | Runs |
|---|---|---|---|
| CPAP machine | 172 | 172 | Yes |
| CPAP machine + LED lights | 181 | 181 | Yes |
| CPAP machine + LED lights + phone charger | 201 | 201 | Yes |
| CPAP machine + LED lights + phone charger + TV | 420 | 420 | Yes |
| CPAP machine + LED lights + phone charger + TV + refrigerator | 1,200 | 1,620 | Yes |
330 W running 330 W starting
| Spec | Value | Printed as | Document | Checked |
|---|---|---|---|---|
| ResMed AirSense 11: rated watts | 73.2 W | Peak power consumption | document.resmed.com (owners manual pdf) | |
| ResMed AirSense 10: rated watts | 104 W | Peak power consumption | document.resmed.com (owners manual pdf) | |
| Philips Respironics DreamStation 2 Advanced: rated amps | 2 A | Electrical: AC Power Consumption | philips.com (owners manual pdf) | |
| React Health Luna G3 CPAP LG3500: rated amps | 2 A | AC Power Consumption | reacthealth.com (owners manual pdf) |
The 4 models we sampled print a median of 172 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 60 to 120 W as typical running watts. Plan for 172 W when it starts.
At 120 V, 172 W works out to 1.4 A. That is the median nameplate draw divided by 120 V. A CPAP machine draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.
The smallest listed size that covers a CPAP machine on its own is 2,000 W. That covers 172 W running and 172 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Honda EU1000i at 900 W running.
We size a CPAP machine at 172 W to start, because it has no motor to start, so it is the running draw. A generator has to cover that starting figure for a moment and the running figure after. Without a motor, the draw is about the same from the moment it switches on.