A furnace blower is rated 750 W on the nameplate, the median of 4 sampled models. Champion's generator chart lists 300 to 800 W running. Sizing uses 1,600 W to start: the top of Champion's starting band, as no maker prints one. The smallest size that covers it alone is 2,000 W.
| Figure | Value | Where it comes from |
|---|---|---|
| Rated draw (nameplate) | 750 W | Median of 4 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating. |
| Typical running (generator maker's chart) | 300 to 800 W | Champion generator wattage chart |
| Starting (generator maker's chart) | 800 to 1,600 W | Champion generator wattage chart |
| Starting watts for sizing | 1,600 W | Used because no sampled maker prints a surge, so it is the top of Champion's starting band. |
| Amps at 120 V | 6.3 A | Rated draw divided by 120 V. |
What was sampled: 1/2 to 3/4 HP ECM blower motor in a 56,000 to 80,000 Btu gas furnace, 115 V.
Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.
| Printed as, document, checked | |||||
|---|---|---|---|---|---|
| Rheem | R921T0603A17M4SNAS | 5.8 | not published | 696 | MOTOR FULL LOAD AMPS, files.myrheem.com, checked |
| Rheem | R951V0603A17M4SCAP | 6.1 | not published | 732 | Motor Full Load Amps, files.myrheem.com, checked |
| York | TM8E060A12MP11 | 6.4 | not published | 768 | Blower A, files.hvacnavigator.com, checked |
| York | TM8V080C16MP12C | 9.6 | not published | 1,152 | Blower Amps, files.hvacnavigator.com, checked |
The smallest listed size that covers 750 W running and 1,600 W starting on its own is 2,000 W.
The smallest current generators in our data that run it alone:
Predator, Open frame
Honda Power Equipment, Inverter
Honda Power Equipment, Inverter
Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.
| Question | Generator running W | Generator starting W | Answer |
|---|---|---|---|
| Will a 2,000 watt generator run a furnace blower? | 2,000 | 2,545 | Yes |
| Will a 3,500 watt generator run a furnace blower? | 3,500 | 4,375 | Yes |
| Will a 5,000 watt generator run a furnace blower? | 5,000 | 5,500 | Yes |
| Will a 7,500 watt generator run a furnace blower? | 7,500 | 9,388 | Yes |
Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.
| Running at once | Running total W | Peak at the largest start W | Runs |
|---|---|---|---|
| Furnace blower | 750 | 1,600 | Yes |
| Furnace blower + LED lights | 759 | 1,609 | Yes |
| Furnace blower + LED lights + phone charger | 779 | 1,629 | Yes |
| Furnace blower + LED lights + phone charger + TV | 998 | 1,848 | Yes |
| Furnace blower + LED lights + phone charger + TV + refrigerator | 1,778 | 2,628 | Yes |
2,472 W running 4,500 W starting
3,240 W running 6,000 W starting
5,376 W running 8,000 W starting
3,456 W running 6,000 W starting
1,035 W running 2,400 W starting
445 W running 1,200 W starting
710 W running 2,400 W starting
| Spec | Value | Printed as | Document | Checked |
|---|---|---|---|---|
| Rheem R921T0603A17M4SNAS: rated amps | 5.8 A | MOTOR FULL LOAD AMPS | files.myrheem.com (spec sheet pdf) | |
| Rheem R951V0603A17M4SCAP: rated amps | 6.1 A | Motor Full Load Amps | files.myrheem.com (spec sheet pdf) | |
| York TM8E060A12MP11: rated amps | 6.4 A | Blower A | files.hvacnavigator.com (spec sheet pdf) | |
| York TM8V080C16MP12C: rated amps | 9.6 A | Blower Amps | files.hvacnavigator.com (spec sheet pdf) |
The 4 models we sampled print a median of 750 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. The Champion generator chart lists 300 to 800 W as typical running watts. Plan for 1,600 W when it starts.
At 120 V, 750 W works out to 6.3 A. That is the median nameplate draw divided by 120 V. A furnace blower draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.
The smallest listed size that covers a furnace blower on its own is 2,000 W. That covers 750 W running and 1,600 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Predator 1800 Portable Generator at 1,400 W running.
We size a furnace blower at 1,600 W to start, because no sampled maker prints a surge, so it is the top of Champion's starting band. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.