How many watts does a dehumidifier use?

A dehumidifier is rated 500 W on the nameplate, the median of 4 sampled models. No generator maker's chart lists this appliance. Sizing uses 500 W to start: its running draw, since no maker or chart prints a surge. The smallest size that covers it alone is 2,000 W.

Dehumidifier figures

Dehumidifier: draw, starting watts and amps Checked on
Figure Value Where it comes from
Rated draw (nameplate) 500 W Median of 4 sampled models: printed watts, or printed amps x 120 V. A nameplate figure is a maximum rating.
Typical running (generator maker's chart) not listed No generator maker's chart lists this appliance.
Starting watts for sizing 500 W Used because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown.
Amps at 120 V 4.2 A Rated draw divided by 120 V.
Energy use per year 379 to 520 kWh Printed on 2 of the 4 sampled models' documents.

What was sampled: 35 to 50 pint portable dehumidifier, 115 V.

The models we sampled

Each row is one real model and the figure its maker prints. Computed watts are printed watts, or printed amps times 120 V when the maker prints amps only.

Dehumidifier models sampled Checked on
Printed as, document, checked
Frigidaire FHDD5033Y1 8.8 470 470 Watts, frigidaire.bynder.com, checked
Frigidaire FHDD3534Y1 7.2 360 360 Watts, frigidaire.bynder.com, checked
GE ADER50LN 5.2 540 540 POWER / RATINGS_Watts, products.geappliances.com, checked
GE ADEL50LR 5.2 530 530 POWER / RATINGS_Watts, products.geappliances.com, checked

The generator you need

The smallest listed size that covers 500 W running and 500 W starting on its own is 2,000 W.

The smallest current generators in our data that run it alone:

Add it to the calculator with other appliances

Will a 2,000 to 7,500 watt generator run it?

Each size is treated as its own running watts, with a starting figure from the median surge of current generators that size. Each question links to the full list for that size.

Dehumidifier on four generator sizes
Question Generator running W Generator starting W Answer
Will a 2,000 watt generator run a dehumidifier? 2,000 2,545 Yes
Will a 3,500 watt generator run a dehumidifier? 3,500 4,375 Yes
Will a 5,000 watt generator run a dehumidifier? 5,000 5,500 Yes
Will a 7,500 watt generator run a dehumidifier? 7,500 9,388 Yes

With other appliances on a 3,500 W generator

Each row adds one more appliance. On this page a 3,500 W generator supplies 3,500 W running and 4,375 W starting.

Dehumidifier with other appliances on a 3,500 W generator
Running at once Running total W Peak at the largest start W Runs
Dehumidifier 500 500 Yes
Dehumidifier + LED lights 509 509 Yes
Dehumidifier + LED lights + phone charger 529 529 Yes
Dehumidifier + LED lights + phone charger + TV 748 748 Yes
Dehumidifier + LED lights + phone charger + TV + refrigerator 1,528 1,948 Yes

Every appliance on one chart

Sources

Where each Dehumidifier value comes from
Spec Value Printed as Document Checked
Frigidaire FHDD5033Y1: rated amps 8.8 A Amps frigidaire.bynder.com (spec sheet pdf)
Frigidaire FHDD5033Y1: rated watts 470 W Watts frigidaire.bynder.com (spec sheet pdf)
Frigidaire FHDD5033Y1: energy use per year 520 kWh/yr annual_energy_consumption_kwh_yr data.energystar.gov (energy star api)
Frigidaire FHDD3534Y1: rated amps 7.2 A Amps frigidaire.bynder.com (spec sheet pdf)
Frigidaire FHDD3534Y1: rated watts 360 W Watts frigidaire.bynder.com (spec sheet pdf)
Frigidaire FHDD3534Y1: energy use per year 379 kWh/yr annual_energy_consumption_kwh_yr data.energystar.gov (energy star api)
GE ADER50LN: rated amps 5.2 A POWER / RATINGS_Amps products.geappliances.com (product page html)
GE ADER50LN: rated watts 540 W POWER / RATINGS_Watts products.geappliances.com (product page html)
GE ADEL50LR: rated amps 5.2 A POWER / RATINGS_Amps products.geappliances.com (product page html)
GE ADEL50LR: rated watts 530 W POWER / RATINGS_Watts products.geappliances.com (product page html)

Questions people ask

How many watts does a dehumidifier use?

The 4 models we sampled print a median of 500 W on the nameplate. A nameplate figure is the maximum the maker rates, not the average while running. No generator maker's chart lists this appliance. Plan for 500 W when it starts.

How many amps does a dehumidifier draw?

At 120 V, 500 W works out to 4.2 A. That is the median nameplate draw divided by 120 V. A dehumidifier draws from an ordinary 120 V outlet. A breaker size printed on a spec sheet is the circuit it needs, not the appliance draw.

What size generator does a dehumidifier need?

The smallest listed size that covers a dehumidifier on its own is 2,000 W. That covers 500 W running and 500 W starting. Anything else running at once adds to that. The smallest current generator in our data that runs it alone is the Honda EU1000i at 900 W running.

How many watts does a dehumidifier need to start?

We size a dehumidifier at 500 W to start, because no sampled maker or generator chart prints a surge, so it is the running draw and the true surge is unknown. A generator has to cover that starting figure for a moment and the running figure after. Motors draw far more for the first second than once running.

Page data checked on