Predator 9000 Portable Generator

The Predator 9000 Portable Generator supplies 7,250 W running and 9,000 W starting on gasoline. It runs a refrigerator, a window AC (12,000 Btu) and LED lights together. It starts a well pump (1 HP), a central AC (3 ton) and a sump pump (1/2 HP), each on its own. It weighs 195 lb (88 kg) and lists at $799.99.

Key figures

Running watts on gasoline
7,250 W source: Output: 7,250 Running Watts (9,000 Max. Starting Watts), checked
Starting watts on gasoline
9,000 W source: Output: 7,250 Running Watts (9,000 Max. Starting Watts), checked
Fuel tank
7.93 gal (30 L) source: Fuel: Recommended fill level 7.93 Gallons/30.00 Liter, checked
Weight
195 lb (88 kg) source: Product Weight 195 lb., checked
Noise with no distance or load stated
78 dBA source: Sound Rating 78 dBA, checked
Warranty
90 days limited retail warranty; emissions-related parts 2 years source: Limited 90 Day Warranty (Retail); emissions control system warranty: "during the two (2) year term of this warranty", checked
List price (MSRP)
$799.99 source: Item 59206 regular_price 799.99, checked
Price per running watt
$0.11 List price divided by running watts on gasoline

We may earn a commission if you buy through these links. It does not change which models we list or how they rank. How this works

What it runs: five common setups

Each setup has every appliance on at once, with the largest motor starting on top of the rest. Running and starting watts for each appliance are the medians from sampled real models; see the appliance chart.

Predator 9000 Portable Generator against five load setups Checked on
Scenario Appliances, all on at once Running needed W Peak as the largest motor starts W Result Limited by
Storm outage refrigerator, furnace blower, sump pump (1/2 HP), LED lights, TV, wi-Fi router, phone charger x2 2,741 3,955 Runs nothing
RV weekend RV air conditioner, microwave, LED lights, TV, phone charger x2 3,379 6,283 Runs nothing
Job site circular saw (7-1/4 inch), air compressor, LED lights, phone charger 3,167 9,329 Cannot run starting watts
Camping mini fridge, coffee maker, LED lights, phone charger x2 1,117 1,587 Runs nothing
CPAP night CPAP machine, LED lights, phone charger 201 201 Runs nothing
  • Starting watts for refrigerator, furnace blower, sump pump (1/2 HP), RV air conditioner, circular saw (7-1/4 inch), air compressor and mini fridge are not printed by the sampled makers, so the upper figure of the generator maker's chart band is used.

Appliances it runs on their own

Each appliance checked alone against 7,250 W running and 9,000 W starting.

Runtime per tank

Every runtime the maker prints, with its load and fuel. Fuel use is the tank size divided by the runtime; propane runtimes are on cylinders of unstated size, so they give none. A row marked est. is a straight line between printed loads, never a guess past them.

Predator 9000 Portable Generator runtimes Checked on
Fuel Load Runtime hours Fuel use gal/h Basis Source
gasoline 50% 13 0.61 printed by the maker manuals.harborfreight.com

Outlets

Predator 9000 Portable Generator receptacles Checked on
Receptacle Count Volts V Amps A GFCI Duplex Source
5-20R 2 120 20 yes yes manuals.harborfreight.com
L5-30R 1 120 30 not published no manuals.harborfreight.com
L14-30R 1 240 30 not published no manuals.harborfreight.com
12V-DC 1 12 not published not published no manuals.harborfreight.com

Noise against the rest of the family

Readings are compared only when both models were measured at the same distance and load.

No other model in this family (Predator 10000 Portable Generator, Predator 10000 Portable Generator (California), Predator 13000 Tri-Fuel Portable Generator, Predator 14500 Tri-Fuel Portable Generator with EFI, Predator 1800 Portable Generator, Predator 4375 Portable Generator, Predator 4375 Portable Generator (California), Predator 5000 Portable Generator, Predator 5000 Portable Generator (California), Predator 6500 Portable Generator, Predator 6500 Portable Generator (California), Predator 9000 Portable Generator (California)) publishes a reading at the same distance and load as this one.

Closest alternatives

The current generators nearest on running watts, fuel, weight, noise and price. The rule is on the methodology page.

Sources

Where each Predator 9000 Portable Generator value comes from
Spec Value Printed as Document Checked
Running watts on gasoline 7,250 W Output: 7,250 Running Watts (9,000 Max. Starting Watts) harborfreight.com (owners manual pdf)
Starting watts on gasoline 9,000 W Output: 7,250 Running Watts (9,000 Max. Starting Watts) harborfreight.com (owners manual pdf)
Fuel tank 7.93 gal (30 L) Fuel: Recommended fill level 7.93 Gallons/30.00 Liter harborfreight.com (owners manual pdf)
Weight 195 lb (88 kg) Product Weight 195 lb. harborfreight.com (product page html)
Noise with no distance or load stated 78 dBA Sound Rating 78 dBA harborfreight.com (product page html)
Warranty 90 days limited retail warranty; emissions-related parts 2 years Limited 90 Day Warranty (Retail); emissions control system warranty: "during the two (2) year term of this warranty" harborfreight.com (owners manual pdf)
List price (MSRP) $799.99 Item 59206 regular_price 799.99 harborfreight.com (product page html)
Runtime on gasoline, 50% load 13 hours Run Time @ 50% load Up to 13 hr. harborfreight.com (owners manual pdf)
Outlet 5-20R 2 x 120 V Electrical Receptacle: Two 3-Prong, duplex NEMA #5-20 120 V GFCI; figure "GFCI AC Receptacles (5-20R)" harborfreight.com (owners manual pdf)
Outlet L5-30R 1 x 120 V Electrical Receptacle: One 3-Prong, NEMA #L5-30 twistlock 120 V harborfreight.com (owners manual pdf)
Outlet L14-30R 1 x 240 V Electrical Receptacle: One 4-Prong, NEMA #L14-30 twistlock 120 V / 240 V harborfreight.com (owners manual pdf)
Outlet 12V-DC 1 x 12 V Electrical Receptacle: One DC Outlet 12 VDC harborfreight.com (owners manual pdf)

FAQ

Will the Predator 9000 Portable Generator run a refrigerator?

Yes. A refrigerator draws about 780 W running, the median of 3 sampled models, and needs 1,200 W to start by the generator maker's chart. The Predator 9000 Portable Generator supplies 7,250 W running and 9,000 W starting, leaving 6,470 W running to spare. Other loads on at the same time share that margin.

How long does the Predator 9000 Portable Generator run at half load?

The Predator 9000 Portable Generator runs about 13 hours on a tank of gasoline at half load, about 3,625 W. The maker prints that figure. The tank holds 7.93 gal (30 L), so it burns about 0.61 gallons an hour. Runtime falls as the load rises.

How loud is the Predator 9000 Portable Generator?

The maker prints 78 dBA with no distance or load stated for the Predator 9000 Portable Generator. This site compares noise only between models measured at the same distance and load. The quietest figure comes from the maker's product page, checked Oct 7, 2026. A reading without both a distance and a load is shown but not ranked.

Does the Predator 9000 Portable Generator have a 30 amp outlet?

Yes. The Predator 9000 Portable Generator has a 30 amp L5-30R and L14-30R receptacle. It has no 50 amp receptacle. It lists 120 V and 240 V output and 7,250 W running, which caps what a 30 amp plug can draw from it. Its full outlet list: 5-20R x2, L5-30R, L14-30R, 12V-DC.

What size is the Predator 9000 Portable Generator?

The Predator 9000 Portable Generator is a 7,500 watt class generator: 7,250 W running and 9,000 W starting on gasoline. Size classes here follow the highest running figure on any fuel. It weighs 195 lb (88 kg). Running watts are what it holds for hours; makers often name models by the higher starting figure.

Page data checked on