Generac iQ3800DF Dual Fuel 50-State

The Generac iQ3800DF Dual Fuel 50-State supplies 3,000 W running and 3,800 W starting on gasoline. It runs a refrigerator, a window AC (12,000 Btu) and LED lights together. They need 1,824 W running and 3,189 W as the largest motor starts. It cannot run a well pump (1 HP), which needs 240 V. It weighs 107 lb (49 kg).

Key figures

Starting watts on gasoline
3,800 W source: Surge Power 3800 VA (Gasoline) / 3400 VA (LP), checked
Running watts on propane
2,700 W source: Rated Power 2700 W (LP), checked
Starting watts on propane
3,400 W source: Surge Power 3400 VA (LP), checked
Fuel tank
3.28 gal (12.4 L) source: Fuel Tank Capacity US gal (L) 3.28 (12.4), checked
Weight
107 lb (49 kg) source: Unit Weight lbs (kg) 107 (48.5), checked
Noise
not published
Warranty
3 years residential, 2 years commercial (limited) source: Warranty- Residential 3 Year Limited; Warranty- Commercial 2 Year Limited, checked
List price (MSRP)
not published
Price per running watt
not published List price divided by running watts on gasoline

What it runs: five common setups

Each setup has every appliance on at once, with the largest motor starting on top of the rest. Running and starting watts for each appliance are the medians from sampled real models; see the appliance chart.

Generac iQ3800DF Dual Fuel 50-State against five load setups Checked on
Scenario Appliances, all on at once Running needed W Peak as the largest motor starts W Result Limited by
Storm outage refrigerator, furnace blower, sump pump (1/2 HP), LED lights, TV, wi-Fi router, phone charger x2 2,741 3,955 Cannot run starting watts
RV weekend RV air conditioner, microwave, LED lights, TV, phone charger x2 3,379 6,283 Cannot run running watts
Job site circular saw (7-1/4 inch), air compressor, LED lights, phone charger 3,167 9,329 Cannot run running watts
Camping mini fridge, coffee maker, LED lights, phone charger x2 1,117 1,587 Runs nothing
CPAP night CPAP machine, LED lights, phone charger 201 201 Runs nothing
  • Starting watts for refrigerator, furnace blower, sump pump (1/2 HP), RV air conditioner, circular saw (7-1/4 inch), air compressor and mini fridge are not printed by the sampled makers, so the upper figure of the generator maker's chart band is used.

Appliances it runs on their own

Each appliance checked alone against 3,000 W running and 3,800 W starting.

Runs (32)

Does not run (14)

Runtime per tank

Every runtime the maker prints, with its load and fuel. Fuel use is the tank size divided by the runtime; propane runtimes are on cylinders of unstated size, so they give none. A row marked est. is a straight line between printed loads, never a guess past them.

Generac iQ3800DF Dual Fuel 50-State runtimes Checked on
Fuel Load Runtime hours Fuel use gal/h Basis Source
gasoline 25% 20 0.16 printed by the maker generac.com
gasoline 50% 13 0.25 printed by the maker generac.com
propane 25% 19 not published printed by the maker generac.com
propane 50% 16 not published printed by the maker generac.com

Outlets

Generac iQ3800DF Dual Fuel 50-State receptacles Checked on
Receptacle Count Volts V Amps A GFCI Duplex Source
5-20R 2 120 20 yes yes generac.com
L5-30R 1 120 30 not published no generac.com

Noise against the rest of the family

Readings are compared only when both models were measured at the same distance and load.

No other model in this family (Generac iQ3500 COsense, Generac iQ3800DF Dual Fuel, Generac iQ5200DF Dual Fuel, Generac iQ5200DF Dual Fuel 50-State) publishes a reading at the same distance and load as this one.

Closest alternatives

The current generators nearest on running watts, fuel, weight, noise and price. The rule is on the methodology page.

Sources

Where each Generac iQ3800DF Dual Fuel 50-State value comes from
Spec Value Printed as Document Checked
Running watts on gasoline 3,000 W Generator Specifications iQ3800DF: Rated Power 3000 W (Gasoline) / 2700 W (LP) generac.com (owners manual pdf)
Starting watts on gasoline 3,800 W Surge Power 3800 VA (Gasoline) / 3400 VA (LP) generac.com (owners manual pdf)
Running watts on propane 2,700 W Rated Power 2700 W (LP) generac.com (owners manual pdf)
Starting watts on propane 3,400 W Surge Power 3400 VA (LP) generac.com (owners manual pdf)
Fuel tank 3.28 gal (12.4 L) Fuel Tank Capacity US gal (L) 3.28 (12.4) generac.com (spec sheet pdf)
Weight 107 lb (49 kg) Unit Weight lbs (kg) 107 (48.5) generac.com (spec sheet pdf)
Noise not published no source
Warranty 3 years residential, 2 years commercial (limited) Warranty- Residential 3 Year Limited; Warranty- Commercial 2 Year Limited generac.com (spec sheet pdf)
List price (MSRP) not published no source
Runtime on gasoline, 25% load 20 hours Run Time at 25% of Rated Load (Hours) 20 (Gas) / 19 (LP - 20lb Tank) generac.com (spec sheet pdf)
Runtime on gasoline, 50% load 13 hours Run Time at 50% of Rated Load (Hours) 13 (Gas) / 16 (LP - 20lb Tank) generac.com (spec sheet pdf)
Runtime on propane, 25% load 19 hours Run Time at 25% of Rated Load (Hours) 20 (Gas) / 19 (LP - 20lb Tank) generac.com (spec sheet pdf)
Runtime on propane, 50% load 16 hours Run Time at 50% of Rated Load (Hours) 13 (Gas) / 16 (LP - 20lb Tank) generac.com (spec sheet pdf)
Outlet 5-20R 2 x 120 V 120V, 20A GFCI Receptacle (NEMA 5-20R), printed twice on the control panel generac.com (spec sheet pdf)
Outlet L5-30R 1 x 120 V 120V, 30A Receptacle (NEMA L5-30R) generac.com (spec sheet pdf)

FAQ

Will the Generac iQ3800DF Dual Fuel 50-State run a refrigerator?

Yes. A refrigerator draws about 780 W running, the median of 3 sampled models, and needs 1,200 W to start by the generator maker's chart. The Generac iQ3800DF Dual Fuel 50-State supplies 3,000 W running and 3,800 W starting, leaving 2,220 W running to spare. Other loads on at the same time share that margin.

How long does the Generac iQ3800DF Dual Fuel 50-State run at half load?

The Generac iQ3800DF Dual Fuel 50-State runs about 13 hours on a tank of gasoline at half load, about 1,500 W. The maker prints that figure. The tank holds 3.28 gal (12.4 L), so it burns about 0.25 gallons an hour. It also prints 20 hours at 25% load. Runtime falls as the load rises.

How loud is the Generac iQ3800DF Dual Fuel 50-State?

The maker of the Generac iQ3800DF Dual Fuel 50-State publishes no noise figure in the documents this site read, so no reading is shown. This site compares noise only between models measured at the same distance and load. Check the owner's manual or ask the maker if noise matters where you will run it.

Does the Generac iQ3800DF Dual Fuel 50-State have a 30 amp outlet?

Yes. The Generac iQ3800DF Dual Fuel 50-State has a 30 amp L5-30R receptacle. It has no 50 amp receptacle. It lists 120 V output only and 3,000 W running, which caps what a 30 amp plug can draw from it. Its full outlet list: 5-20R x2, L5-30R.

What size is the Generac iQ3800DF Dual Fuel 50-State?

The Generac iQ3800DF Dual Fuel 50-State is a 3,000 watt class generator: 3,000 W running and 3,800 W starting on gasoline. Size classes here follow the highest running figure on any fuel. It weighs 107 lb (49 kg). Running watts are what it holds for hours; makers often name models by the higher starting figure.

Page data checked on