Predator 3500 Super Quiet Inverter Generator
Predator, Inverter
- Running
- 3,000 W
- Starting
- 3,500 W
- Weight
- 102 lb
The Generac iQ3500 COsense supplies 3,000 W running and 3,500 W starting on gasoline. It runs a refrigerator, a window AC (12,000 Btu) and LED lights together. They need 1,824 W running and 3,189 W as the largest motor starts. It cannot run a well pump (1 HP), which needs 240 V. It weighs 109.1 lb (49.5 kg).
Each setup has every appliance on at once, with the largest motor starting on top of the rest. Running and starting watts for each appliance are the medians from sampled real models; see the appliance chart.
| Scenario | Appliances, all on at once | Running needed W | Peak as the largest motor starts W | Result | Limited by |
|---|---|---|---|---|---|
| Storm outage | refrigerator, furnace blower, sump pump (1/2 HP), LED lights, TV, wi-Fi router, phone charger x2 | 2,741 | 3,955 | Cannot run | starting watts |
| RV weekend | RV air conditioner, microwave, LED lights, TV, phone charger x2 | 3,379 | 6,283 | Cannot run | running watts |
| Job site | circular saw (7-1/4 inch), air compressor, LED lights, phone charger | 3,167 | 9,329 | Cannot run | running watts |
| Camping | mini fridge, coffee maker, LED lights, phone charger x2 | 1,117 | 1,587 | Runs | nothing |
| CPAP night | CPAP machine, LED lights, phone charger | 201 | 201 | Runs | nothing |
Each appliance checked alone against 3,000 W running and 3,500 W starting.
Every runtime the maker prints, with its load and fuel. Fuel use is the tank size divided by the runtime; propane runtimes are on cylinders of unstated size, so they give none. A row marked est. is a straight line between printed loads, never a guess past them.
| Fuel | Load | Runtime hours | Fuel use gal/h | Basis | Source |
|---|---|---|---|---|---|
| gasoline | 25% | 14.1 | 0.18 | printed by the maker | generac.com |
| gasoline | 50% | 8.9 | 0.29 | printed by the maker | generac.com |
| Receptacle | Count | Volts V | Amps A | GFCI | Duplex | Source |
|---|---|---|---|---|---|---|
| 5-20R | 1 | 120 | 20 | not published | yes | generac.com |
| L5-30R | 1 | 120 | 30 | not published | no | generac.com |
Readings are compared only when both models were measured at the same distance and load.
No other model in this family (Generac iQ3800DF Dual Fuel, Generac iQ3800DF Dual Fuel 50-State, Generac iQ5200DF Dual Fuel, Generac iQ5200DF Dual Fuel 50-State) publishes a reading at the same distance and load as this one.
The current generators nearest on running watts, fuel, weight, noise and price. The rule is on the methodology page.
Predator, Inverter
Westinghouse Outdoor Power Equipment, Inverter
Honda Power Equipment, Inverter
| Spec | Value | Printed as | Document | Checked |
|---|---|---|---|---|
| Running watts on gasoline | 3,000 W | Generator Specifications iQ3500: Rated Power 3000 W | generac.com (owners manual pdf) | |
| Starting watts on gasoline | 3,500 W | Starting Power 3500 W | generac.com (owners manual pdf) | |
| Fuel tank | 2.6 gal (9.8 L) | Fuel Tank Capacity gal (L) 2.6 (10) | generac.com (spec sheet pdf) | |
| Weight | 109.1 lb (49.5 kg) | Unit Weight lbs (kg) 109.1 (49.5) | generac.com (spec sheet pdf) | |
| Noise | not published | no source | ||
| Warranty | 3 years residential, 2 years commercial (limited) | Warranty- Residential 3 Year Limited; Warranty- Commercial 2 Year Limited | generac.com (spec sheet pdf) | |
| List price (MSRP) | not published | no source | ||
| Runtime on gasoline, 25% load | 14.1 hours | Run Time at 25% of Rated Load (Hours) 14.1 | generac.com (spec sheet pdf) | |
| Runtime on gasoline, 50% load | 8.9 hours | Run Time at 50% of Rated Load (Hours) 8.9 | generac.com (spec sheet pdf) | |
| Outlet 5-20R | 1 x 120 V | 120V, 20A Receptacle; Figure 2-3. 120 VAC, Duplex Receptacle | generac.com (owners manual pdf) | |
| Outlet L5-30R | 1 x 120 V | 120V, 30A Receptacle (NEMA L5-30R) | generac.com (owners manual pdf) |
Yes. A refrigerator draws about 780 W running, the median of 3 sampled models, and needs 1,200 W to start by the generator maker's chart. The Generac iQ3500 COsense supplies 3,000 W running and 3,500 W starting, leaving 2,220 W running to spare. Other loads on at the same time share that margin.
The Generac iQ3500 COsense runs about 8.9 hours on a tank of gasoline at half load, about 1,500 W. The maker prints that figure. The tank holds 2.6 gal (9.8 L), so it burns about 0.29 gallons an hour. It also prints 14.1 hours at 25% load. Runtime falls as the load rises.
The maker of the Generac iQ3500 COsense publishes no noise figure in the documents this site read, so no reading is shown. This site compares noise only between models measured at the same distance and load. Check the owner's manual or ask the maker if noise matters where you will run it.
Yes. The Generac iQ3500 COsense has a 30 amp L5-30R receptacle. It has no 50 amp receptacle. It lists 120 V output only and 3,000 W running, which caps what a 30 amp plug can draw from it. Its full outlet list: 5-20R, L5-30R.
The Generac iQ3500 COsense is a 3,000 watt class generator: 3,000 W running and 3,500 W starting on gasoline. Size classes here follow the highest running figure on any fuel. It weighs 109.1 lb (49.5 kg). Running watts are what it holds for hours; makers often name models by the higher starting figure.