Generac Guardian 10 kW

The Generac Guardian 10 kW supplies 9,000 W running on natural gas and 10,000 W on LP, with no published starting figure. It runs a refrigerator, a window AC (12,000 Btu) and LED lights together. It starts a well pump (1 HP), a central AC (3 ton) and a sump pump (1/2 HP), each on its own.

Key figures

Running watts on natural gas
9,000 W source: Rated maximum continuous power capacity (NG): 9,000 Watts*, checked
Starting watts on natural gas
not published
Running watts on propane
10,000 W source: Rated maximum continuous power capacity (LP): 10,000 Watts*, checked
Starting watts on propane
not published
Weight
338 lb (153 kg) source: Unit weight (lb / kg): 338 / 153, checked
Noise at 23 ft (load not stated)
61 dBA source: Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load, checked
Warranty
5 years or 2,000 hours, whichever occurs first: parts, labor and limited travel in years 1 and 2, parts only in year 3, engine short block and alternator only in years 4 and 5 source: Warranty Coverage: Five (5) years or two-thousand (2,000) hours, whichever occurs first, checked
List price (MSRP)
not published
Price per running watt
not published List price divided by running watts on natural gas

What it runs: five common setups

Each setup has every appliance on at once, with the largest motor starting on top of the rest. Running and starting watts for each appliance are the medians from sampled real models; see the appliance chart.

Generac Guardian 10 kW against five load setups Checked on
Scenario Appliances, all on at once Running needed W Peak as the largest motor starts W Result Limited by
Storm outage refrigerator, furnace blower, sump pump (1/2 HP), LED lights, TV, wi-Fi router, phone charger x2 2,741 3,955 Runs nothing
RV weekend RV air conditioner, microwave, LED lights, TV, phone charger x2 3,379 6,283 Runs nothing
Job site circular saw (7-1/4 inch), air compressor, LED lights, phone charger 3,167 9,329 Cannot run starting watts
Camping mini fridge, coffee maker, LED lights, phone charger x2 1,117 1,587 Runs nothing
CPAP night CPAP machine, LED lights, phone charger 201 201 Runs nothing
  • Starting watts for refrigerator, furnace blower, sump pump (1/2 HP), RV air conditioner, circular saw (7-1/4 inch), air compressor and mini fridge are not printed by the sampled makers, so the upper figure of the generator maker's chart band is used.

Appliances it runs on their own

Each appliance checked alone against 9,000 W running and 9,000 W (no starting figure published, so its running watts).

Fuel use

A standby generator runs as long as its gas supply lasts. These are the maker's printed fuel consumption figures.

Generac Guardian 10 kW fuel consumption Checked on
Fuel Load Fuel use Unit Source
natural gas 50% 101 ft3/h generac.com
LP (propane) 50% 36 ft3/h generac.com
LP (propane) 50% 0.97 gal/h generac.com
natural gas 100% 127 ft3/h generac.com
LP (propane) 100% 54 ft3/h generac.com
LP (propane) 100% 1.48 gal/h generac.com

Outlets

A home standby generator has no outlets on the unit. It connects to the house wiring through a transfer switch installed by a licensed electrician. Output: 120/240 V.

Noise against the rest of the family

Readings are compared only when both models were measured at the same distance and load.

No other model in this family (Generac Guardian 14 kW, Generac Guardian 18 kW, Generac Guardian 22 kW, Generac Guardian 24 kW, Generac Guardian 26 kW) publishes a reading at the same distance and load as this one.

Closest alternatives

The current generators nearest on running watts, fuel, weight, noise and price. The rule is on the methodology page.

  • Kohler 10RESV

    KOHLER Home Generators, Home standby

    Running
    9,000 W
    Starting
    n/p
    Weight
    428 lb
    List $3,946
  • Kohler 12RESV

    KOHLER Home Generators, Home standby

    Running
    11,000 W
    Starting
    n/p
    Weight
    433 lb
    List $4,384

Sources

Where each Generac Guardian 10 kW value comes from
Spec Value Printed as Document Checked
Running watts on natural gas 9,000 W Rated maximum continuous power capacity (NG): 9,000 Watts* generac.com (spec sheet pdf)
Starting watts on natural gas not published no source
Running watts on propane 10,000 W Rated maximum continuous power capacity (LP): 10,000 Watts* generac.com (spec sheet pdf)
Starting watts on propane not published no source
Weight 338 lb (153 kg) Unit weight (lb / kg): 338 / 153 generac.com (spec sheet pdf)
Noise at 23 ft (load not stated) 57 dBA Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test low-speed exercise mode generac.com (spec sheet pdf)
Noise at 23 ft (load not stated) 61 dBA Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load generac.com (spec sheet pdf)
Warranty 5 years or 2,000 hours, whichever occurs first: parts, labor and limited travel in years 1 and 2, parts only in year 3, engine short block and alternator only in years 4 and 5 Warranty Coverage: Five (5) years or two-thousand (2,000) hours, whichever occurs first generac.com (other primary)
List price (MSRP) not published no source
Natural gas use at 50% load 101 ft3/h Fuel consumption, Natural gas, 1/2 Load, ft3/hr (m3/hr): 101 (2.86) generac.com (spec sheet pdf)
Propane use at 50% load 36 ft3/h Fuel consumption, Liquid propane, 1/2 Load, ft3/hr (gal/hr) [L/hr]: 36 (0.97) [3.66] generac.com (spec sheet pdf)
Propane use at 50% load 0.97 gal/h Fuel consumption, Liquid propane, 1/2 Load, ft3/hr (gal/hr) [L/hr]: 36 (0.97) [3.66] generac.com (spec sheet pdf)
Natural gas use at 100% load 127 ft3/h Fuel consumption, Natural gas, Full Load, ft3/hr (m3/hr): 127 (3.60) generac.com (spec sheet pdf)
Propane use at 100% load 54 ft3/h Fuel consumption, Liquid propane, Full Load, ft3/hr (gal/hr) [L/hr]: 54 (1.48) [5.62] generac.com (spec sheet pdf)
Propane use at 100% load 1.48 gal/h Fuel consumption, Liquid propane, Full Load, ft3/hr (gal/hr) [L/hr]: 54 (1.48) [5.62] generac.com (spec sheet pdf)

FAQ

Will the Generac Guardian 10 kW run a refrigerator?

Yes. A refrigerator draws about 780 W running, the median of 3 sampled models, and needs 1,200 W to start by the generator maker's chart. The Generac Guardian 10 kW supplies 9,000 W running with no published starting figure, leaving 8,220 W running to spare. Other loads on at the same time share that margin.

How long does the Generac Guardian 10 kW run at half load?

A standby generator runs as long as its gas supply lasts, so it has no tank runtime. At half load the Generac Guardian 10 kW burns 101 ft3/h of natural gas and 36 ft3/h of LP, by the maker's fuel table. At full load it burns 127 ft3/h of natural gas and 54 ft3/h of LP.

How loud is the Generac Guardian 10 kW?

The maker prints 57 dBA at 23 ft (load not stated) and 61 dBA at 23 ft (load not stated) for the Generac Guardian 10 kW. This site compares noise only between models measured at the same distance and load. The quietest figure comes from the maker's spec sheet, checked Oct 7, 2026.

Does the Generac Guardian 10 kW have a 30 amp outlet?

No. The Generac Guardian 10 kW is a home standby generator with no outlets on the unit. It connects to the house wiring through a transfer switch installed by a licensed electrician. It supplies 9 kW on natural gas at 120/240 V.

What size is the Generac Guardian 10 kW?

The Generac Guardian 10 kW is a 10,000 watt class home standby generator: 9 kW on natural gas and 10 kW on LP, with no published starting figure. Size classes here follow the highest running figure on any fuel. It weighs 338 lb (153 kg). It runs at 120/240 V.