Kohler 26RCA

The Kohler 26RCA supplies 24,000 W running on natural gas and 26,000 W on LP, with no published starting figure. It runs a refrigerator, a window AC (12,000 Btu) and LED lights together. It starts a well pump (1 HP), a central AC (3 ton) and a sump pump (1/2 HP), each on its own.

Key figures

Starting watts on natural gas
not published
Starting watts on propane
not published
Noise at 23 ft (load not stated)
56 dBA source: Generator Set Sound Data: 26RCA sound levels are 56 dB(A) during engine exercise, checked
Warranty
5 years or 2,000 hours, premium limited standby warranty covering parts, labor and travel for the full period source: Premium 5-yr/2000-hr Limited Warranty Included, checked
List price (MSRP)
$7,546 source: Starting at $7,546 MSRP*, checked
Price per running watt
$0.31 List price divided by running watts on natural gas

What it runs: five common setups

Each setup has every appliance on at once, with the largest motor starting on top of the rest. Running and starting watts for each appliance are the medians from sampled real models; see the appliance chart.

Kohler 26RCA against five load setups Checked on
Scenario Appliances, all on at once Running needed W Peak as the largest motor starts W Result Limited by
Storm outage refrigerator, furnace blower, sump pump (1/2 HP), LED lights, TV, wi-Fi router, phone charger x2 2,741 3,955 Runs nothing
RV weekend RV air conditioner, microwave, LED lights, TV, phone charger x2 3,379 6,283 Runs nothing
Job site circular saw (7-1/4 inch), air compressor, LED lights, phone charger 3,167 9,329 Runs nothing
Camping mini fridge, coffee maker, LED lights, phone charger x2 1,117 1,587 Runs nothing
CPAP night CPAP machine, LED lights, phone charger 201 201 Runs nothing
  • Starting watts for refrigerator, furnace blower, sump pump (1/2 HP), RV air conditioner, circular saw (7-1/4 inch), air compressor and mini fridge are not printed by the sampled makers, so the upper figure of the generator maker's chart band is used.

Appliances it runs on their own

Each appliance checked alone against 24,000 W running and 24,000 W (no starting figure published, so its running watts).

Fuel use

A standby generator runs as long as its gas supply lasts. These are the maker's printed fuel consumption figures.

Kohler 26RCA fuel consumption Checked on
Fuel Load Fuel use Unit Source
natural gas 100% 290 ft3/h techcomm.rehlko.com
natural gas 75% 238 ft3/h techcomm.rehlko.com
natural gas 50% 180 ft3/h techcomm.rehlko.com
natural gas 25% 137 ft3/h techcomm.rehlko.com
LP (propane) 100% 129 ft3/h techcomm.rehlko.com
LP (propane) 75% 111 ft3/h techcomm.rehlko.com
LP (propane) 50% 85 ft3/h techcomm.rehlko.com
LP (propane) 25% 64 ft3/h techcomm.rehlko.com

Outlets

A home standby generator has no outlets on the unit. It connects to the house wiring through a transfer switch installed by a licensed electrician. Output: 120/240 V.

Noise against the rest of the family

Readings are compared only when both models were measured at the same distance and load.

No other model in this family (Kohler 14RCA, Kohler 20RCA) publishes a reading at the same distance and load as this one.

Closest alternatives

The current generators nearest on running watts, fuel, weight, noise and price. The rule is on the methodology page.

Sources

Where each Kohler 26RCA value comes from
Spec Value Printed as Document Checked
Running watts on natural gas 24,000 W Generator Ratings, Standby Ratings, Natural Gas kW/kVA: 24/24 (2F8, 120/240 V, 1 phase, 60 Hz) techcomm.rehlko.com (spec sheet pdf)
Starting watts on natural gas not published no source
Running watts on propane 26,000 W Generator Ratings, Standby Ratings, LPG kW/kVA: 26/26 (2F8, 120/240 V, 1 phase, 60 Hz) techcomm.rehlko.com (spec sheet pdf)
Starting watts on propane not published no source
Weight 670 lb (304 kg) Generator Set Dimensions and Weights, Shipping Weights, 26RCA Generator Set: 304 kg (670 lb.) techcomm.rehlko.com (spec sheet pdf)
Noise at 23 ft (load not stated) 56 dBA Generator Set Sound Data: 26RCA sound levels are 56 dB(A) during engine exercise techcomm.rehlko.com (spec sheet pdf)
Noise at 23 ft (load not stated) 67 dBA Generator Set Sound Data: 67 dB(A) during full-speed generator diagnostics and normal operation techcomm.rehlko.com (spec sheet pdf)
Warranty 5 years or 2,000 hours, premium limited standby warranty covering parts, labor and travel for the full period Premium 5-yr/2000-hr Limited Warranty Included techcomm.rehlko.com (spec sheet pdf)
List price (MSRP) $7,546 Starting at $7,546 MSRP* kohlerhomeenergy.rehlko.com (product page html)
Natural gas use at 100% load 290 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, Natural Gas, 100% load: 8.2 (290) techcomm.rehlko.com (spec sheet pdf)
Natural gas use at 75% load 238 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, Natural Gas, 75% load: 6.7 (238) techcomm.rehlko.com (spec sheet pdf)
Natural gas use at 50% load 180 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, Natural Gas, 50% load: 5.1 (180) techcomm.rehlko.com (spec sheet pdf)
Natural gas use at 25% load 137 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, Natural Gas, 25% load: 3.9 (137) techcomm.rehlko.com (spec sheet pdf)
Propane use at 100% load 129 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, LPG, 100% load: 3.6 (129) techcomm.rehlko.com (spec sheet pdf)
Propane use at 75% load 111 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, LPG, 75% load: 3.1 (111) techcomm.rehlko.com (spec sheet pdf)
Propane use at 50% load 85 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, LPG, 50% load: 2.4 (85) techcomm.rehlko.com (spec sheet pdf)
Propane use at 25% load 64 ft3/h Operation Requirements, Fuel Consumption, m3/hr. (cfh) @ 60Hz, LPG, 25% load: 1.8 (64) techcomm.rehlko.com (spec sheet pdf)

FAQ

Will the Kohler 26RCA run a refrigerator?

Yes. A refrigerator draws about 780 W running, the median of 3 sampled models, and needs 1,200 W to start by the generator maker's chart. The Kohler 26RCA supplies 24,000 W running with no published starting figure, leaving 23,220 W running to spare. Other loads on at the same time share that margin.

How long does the Kohler 26RCA run at half load?

A standby generator runs as long as its gas supply lasts, so it has no tank runtime. At half load the Kohler 26RCA burns 180 ft3/h of natural gas and 85 ft3/h of LP, by the maker's fuel table. At full load it burns 290 ft3/h of natural gas and 129 ft3/h of LP.

How loud is the Kohler 26RCA?

The maker prints 56 dBA at 23 ft (load not stated) and 67 dBA at 23 ft (load not stated) for the Kohler 26RCA. This site compares noise only between models measured at the same distance and load. The quietest figure comes from the maker's spec sheet, checked Oct 7, 2026.

Does the Kohler 26RCA have a 30 amp outlet?

No. The Kohler 26RCA is a home standby generator with no outlets on the unit. It connects to the house wiring through a transfer switch installed by a licensed electrician. It supplies 24 kW on natural gas at 120/240 V.

What size is the Kohler 26RCA?

The Kohler 26RCA is a 26,000 watt class home standby generator: 24 kW on natural gas and 26 kW on LP, with no published starting figure. Size classes here follow the highest running figure on any fuel. It weighs 670 lb (304 kg). It runs at 120/240 V.

Page data checked on