What size generator do you need for a 50 amp RV?

A 50 amp RV has two 120 V legs of 50 A each, so the plug can carry up to 12,000 W. Few rigs use all of it. Size from what you run at once, usually two rooftop ACs, the fridge and kitchen loads, and make sure it has a 120/240 V outlet that can feed both legs.

Updated

Why 50 amp is so much bigger than 30 amp

A 50 amp RV uses a four-prong NEMA 14-50 plug. The receptacle is rated 50 A at 125/250 V, with two hots, a neutral and a ground [18]. Each hot leg carries up to 50 A at 120 V, and the two legs together give 100 A at 120 V. That's 12,000 W.

A 30 amp RV, by comparison, has one leg of 30 A at 120 V, which is 3,600 W [17]. So "50 amp" means more than three times the capacity of "30 amp," not a bit more. The 30 amp RV guide covers the smaller system.

Most 50 amp rigs split their loads across the two legs: one rooftop AC on each, the microwave on one, the water heater element on the other. That split matters when you pick a generator.

Add up what you actually run

You don't need a 12,000 W generator to run a 50 amp RV. You need one that covers your real load. A typical hot-weather list:

Add the running watts. Then add the largest single starting surge, which is almost always one AC compressor. If both ACs could start together, stagger them with the thermostat or a delay so the generator only sees one surge at a time.

Example: a refrigerator, LED lights, a phone charger and a TV
Appliance RunningW Starting for sizingW
Refrigerator 780 W 1,200 W (chart)
LED lights 9 W 9 W
Phone charger 20 W 20 W
TV 219 W 219 W
Running total
1,028 W
Starting peak
1,448 W
Recommended size
2,000 W

The running total divided by the continuous-load factor of 0.8 is 1,285 W. The starting peak is the running total plus the largest single surge. The larger of the two, rounded up to the next listed size, is the recommendation. Starting watts for Refrigerator come from the generator maker's chart, because the sampled spec sheets print no surge figure.

Size your own list in the calculator

The outlet decides whether both legs work

This is where people get caught. A generator with only 120 V outlets, or a 120 V-only TT-30R, can feed one leg of a 50 amp RV through an adapter. Many adapters jumper that single leg to both sides of the RV panel, so everything works, but the total is limited to what that one 120 V outlet can deliver.

To use both legs, the generator needs a 120/240 V 14-50R outlet, or an L14-30R with an adapter rated for the job [19]. The generators with a 50 amp outlet page lists models whose spec sheets show a 14-50R.

Check one more thing: how the generator's 240 V output is split. A generator rated for a given number of watts usually can't put all of them on one leg. If its manual lists amps per receptacle, those per-outlet figures are your real limit.

Typical sizes for a 50 amp RV

With one AC running and modest loads, a mid-size portable generator often does it. See what a 5000 watt generator will run and compare models in the 5500 watt class.

With two ACs, a fridge and the microwave at once, you're into the larger portable range. See what a 7500 watt generator will run and what a 9000 watt generator will run. Going larger buys margin for heat and altitude, at the cost of fuel and weight.

Two parallel-capable inverter generators are another route, if the parallel kit has a 50 amp outlet. The parallel-capable page lists models that support it.

Fuel and noise on the road

Dual fuel models let you run on propane from the RV's tanks or a separate cylinder, which avoids carrying gasoline. Propane gives fewer watts per hour of runtime because it holds less energy per gallon: about 91,452 Btu against 120,214 Btu for gasoline. The gas vs propane guide compares them, and the dual fuel generators page shows each model's running watts on both fuels.

Noise matters at campgrounds. Bigger generators are louder, and published decibel figures are only comparable at the same distance and load. The quiet generators page shows each figure with its test condition.

Run it safely

Run the generator outside only, at least 20 ft from the RV and any occupied space, with the exhaust pointed away. Never run it inside an enclosed space [7]. Keep the RV's CO alarm tested and working. Have any permanent wiring change, such as a generator inlet on the RV, done by a qualified RV technician or licensed electrician.

FAQ

Do I need a 12,000 watt generator for a 50 amp RV?

No. That's the most the plug can carry, not what the RV draws. Size the generator from what you run at once, usually one or two ACs plus the fridge and kitchen loads. Add the running watts and the biggest AC surge in the calculator to get your number.

Can I run a 50 amp RV on a 30 amp generator outlet?

Yes, with a 30 to 50 amp adapter, but you only get what the 30 amp outlet can supply on one leg. That usually covers one AC and light loads, not two ACs. To use both legs of a 50 amp RV, the generator needs a 120/240 V outlet such as a 14-50R.

What size generator runs two RV air conditioners?

One whose running watts cover both ACs plus everything else running, and whose starting watts cover the total plus one AC's surge, assuming the two don't start together. Check that the generator splits its output across both legs. Look up your ACs on the RV AC page and add them in the calculator.

Is an inverter generator better for a 50 amp RV?

Inverter models are quieter at light load and produce cleaner power, which suits campgrounds and RV electronics. Large open-frame units give more watts per dollar and often have the 14-50R outlet built in. Two inverter generators in parallel are a middle path if the parallel kit has a 50 amp outlet.

Page data checked on