Watts to amps calculator

To convert watts to amps, divide the watts by the volts times the power factor. A 5,000 W load at 120 V with a power factor of 1 draws 41.67 A. On split-phase 240 V, with the load across both hot legs, it draws 20.83 A on each leg.

Phase
Set by the phase choice; type another voltage if yours differs.
Defaults to 1, where watts and volt-amperes are equal. Enter the figure from your equipment if it prints one.
Result41.67A

5,000 W at 120 V and a power factor of 1 draws 41.67 A. Single phase, 120 V: one hot leg and neutral.

The smallest listed generator size at or above 5,000 W running is 5,000 W.

The formula

amps = watts / (volts x power factor)

Single phase uses one hot leg and neutral, 120 V on US generators. Split phase puts a 240 V load across both hot legs, and the amps shown are per leg. A power factor of 1 gives the amps for the watts as stated; a lower power factor means more amps for the same watts.

At each listed generator size

Amps at each listed generator size, power factor 1
Generator size W At 120 V A At 240 V, per leg A
2,000 16.67 8.33
2,500 20.83 10.42
3,000 25 12.5
3,500 29.17 14.58
4,000 33.33 16.67
4,500 37.5 18.75
5,000 41.67 20.83
5,500 45.83 22.92
6,000 50 25
6,500 54.17 27.08
7,000 58.33 29.17
7,500 62.5 31.25
8,000 66.67 33.33
9,000 75 37.5
10,000 83.33 41.67
12,000 100 50
15,000 125 62.5
20,000 166.67 83.33
22,000 183.33 91.67
24,000 200 100
26,000 216.67 108.33

Other converters